Indicator: 10~100ppm
Measuring Range: 5~100ppm, Number of Pump Strokes 2
Sampling Time: 2 minute per pump stroke
Colour Change: Yellow → Pale blue
Reaction Principle: CH3C6H10OH + Cr6++ H3PO4 → Cr3+
Coefficient of Variation: 10% (for 5 to 50 ppm), 5% (for 50 to 250 ppm)
Nr. of tests: 10
Pump: GV-100S/110S
Performance
| Measuring Range | 5 to 100 ppm |
| Number of Pump Strokes | 2 |
| Correction Factor | 1 |
| Sampling Time | 2 minutes per pump stroke |
| Detecting Limit | 1 ppm (n=2) |
| Colour Change | Yellow → Pale blue |
| Reaction Principle | CH3C6H10OH + Cr6++ H3PO4 → Cr3+ |
| Coefficient of Variation | 10% (for 5 to 50 ppm), 5% (for 50 to 250 ppm) |
| Shelf Life | 2 Years |
| Corrections for temperature & humidity | Temperature correction is necessary |
| Store the tubes at cool and dark place. | |
Possible coexisting substances and their interferences (NOTE)
| Substance | Concentration | Interference | Change colour by itself to |
| Cyclic alcohols | + | Pale blue | |
| Aromatic HCs | + | Pale blue |
| Calibration gas generation | Vaper pressure method |
| TLV-TWA | TLV-STEL | Explosive range |
| 50 ppm(2014) | - | 1% or higher |