GW INSTEK GDS-1102A-U 数字示波器 (100Mhz, 2CH, 1Gsa/s)

 
 
GDS-1102A-U
 
VERTICAL
Channels
 
2
 
Bandwidth
 
DC
~100MHz(-3dB)
 
Rise Time
 
<3.5ns approx="" span="">
 
Sensitivity 2mV/div ~ 10V/div (1-2-5 increments)
Accuracy ±(3% x |Readout| + 0.1 div + 1mV)
Input Coupling AC, DC & Ground
Input Impedance 1MΩ±2%, ~15pF
Polarity Normal & Invert
Maximum Input 300V (DC+AC peak), CATII
Waveform Signal Process + , - , x, FFT, FFTrms ,Zoom FFT
Offset Range   2mV/div ~ 50mV/div: ±0.4V  100mV/div ~ 500mV/div: ±4V  1V/div ~ 5V/div: ±40V  10V/div: ±300V
Bandwidth Limit 20MHz (-3dB)
TRIGGER
Sources CH1 , CH2 , Line , EXT
Modes Auto, Normal, Single, TV, Edge, Pulse Width
Coupling AC , DC , LF rej. , HF rej. , Noise rej.
Sensitivity DC ~ 25MHz: Approx. 0.5div or 5mV;  25MHz ~ 70/100/150MHz: Approx. 1.5div or 15mV
EXT TRIGGER
Range ±15V
Sensitivity DC ~ 25MHz : ~ 50mV ; 25M ~ 70/100/150MHz : ~15mV
Input Impedance 1MΩ±2% , ~ 15pF
Maximum Input 300V (DC AC peak) , CATII
HORIZONTAL
Range 1ns/div ~ 50s/div (1-2.5-5 increments); ROLL : 50ms/div ~ 50s/div
Modes Main, Window, Window Zoom, Roll, X-Y
Accuracy ±0.01%
Pre-Trigger 10 div maximum
Post-Trigger 1000 div
X-Y MODE
X-Axis Input Channel 1
Y-Axis Input Channel 2
Phase Shift ±3°at 100kHz
SIGNAL ACQUISITION
Real-Time Sample Rate 1GSa/s maximum
Equivalent Sample Rate 25GSa/s maximum
Vertical Resolution 8 Bits
  2 Mega Points maximum
Acquisition Mode Normal, Peak Detect, Average
Peak Detection 10ns (500ns/div ~ 10s/div)
Average 2 , 4 , 8 , 16 , 32 , 64 , 128 , 256
CURSORS AND MEASUREMENT
Voltage Measurement Vpp ,Vamp ,Vavg ,Vrms ,Vhi ,Vlo ,Vmax ,Vmin ,Rise Preshoot/Overshoot ,Fall Preshoot/Overshoot
Time Measurement Freq ,Period ,Rise Time ,Fall Time ,Positive Width ,Negative Width ,Duty Cycle
Cursors Measurement Voltage difference between cursors (V)  Time difference between cursors (T)
Auto Counter   Resolution : 6 digits Accuracy: 2% Signal Source: All available trigger source except the Video trigger mode
ADJUSTABLE PROBE COMPENSATION SIGNAL
Frequency Range 1kHz ~ 100kHz, 1kHz/STEP
Duty Cycle Range 5% ~ 95%, 5%/STEP
CONTROL PANEL FUNCTION
Autoset Adjust Vertical VOLT/DIV, Horizontal TIME/DIV, and Trigger level automatically
Save Setup Up to 15 sets of measurement conditions
Save Waveform 15 sets of waveform
DISPLAY
TFT LCD Type 5.7 inch
Display Resolution 234(Vertically) x 320(Horizontally) Dots
Display Graticule 8 x 10 divisions
Display Brightness Adjustable
INTERFACE
USB Device USB1.1 & 2.0 full speed compatible (Pictbridge Compatibility Printers Supported)
USB Host Image (BMP), waveform data (CSV), and setup (SET)
POWER SOURCE
Line Voltage Range AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection
MISCELLANEOUS
Multi-Language Menu Available
Onscreen Help Available
DIMENSIONS & WEIGHT
  310(W) x 142 (H) x 140(D)mm, Approx. 2.5kg
Details

 Catalog

 

 
GDS-1102A-U
 
VERTICAL
Channels
 
2
 
Bandwidth
 
DC
~100MHz(-3dB)
 
Rise Time
 
<3.5ns approx="" span="">
 
Sensitivity 2mV/div ~ 10V/div (1-2-5 increments)
Accuracy ±(3% x |Readout| + 0.1 div + 1mV)
Input Coupling AC, DC & Ground
Input Impedance 1MΩ±2%, ~15pF
Polarity Normal & Invert
Maximum Input 300V (DC+AC peak), CATII
Waveform Signal Process + , - , x, FFT, FFTrms ,Zoom FFT
Offset Range
 
2mV/div ~ 50mV/div: ±0.4V 
100mV/div ~ 500mV/div: ±4V 
1V/div ~ 5V/div: ±40V 
10V/div: ±300V
Bandwidth Limit 20MHz (-3dB)
TRIGGER
Sources CH1 , CH2 , Line , EXT
Modes Auto, Normal, Single, TV, Edge, Pulse Width
Coupling AC , DC , LF rej. , HF rej. , Noise rej.
Sensitivity DC ~ 25MHz: Approx. 0.5div or 5mV; 
25MHz ~ 70/100/150MHz: Approx. 1.5div or 15mV
EXT TRIGGER
Range ±15V
Sensitivity DC ~ 25MHz : ~ 50mV ; 25M ~ 70/100/150MHz : ~15mV
Input Impedance 1MΩ±2% , ~ 15pF
Maximum Input 300V (DC AC peak) , CATII
HORIZONTAL
Range 1ns/div ~ 50s/div (1-2.5-5 increments); ROLL : 50ms/div ~ 50s/div
Modes Main, Window, Window Zoom, Roll, X-Y
Accuracy ±0.01%
Pre-Trigger 10 div maximum
Post-Trigger 1000 div
X-Y MODE
X-Axis Input Channel 1
Y-Axis Input Channel 2
Phase Shift ±3°at 100kHz
SIGNAL ACQUISITION
Real-Time Sample Rate 1GSa/s maximum
Equivalent Sample Rate 25GSa/s maximum
Vertical Resolution 8 Bits
  2 Mega Points maximum
Acquisition Mode Normal, Peak Detect, Average
Peak Detection 10ns (500ns/div ~ 10s/div)
Average 2 , 4 , 8 , 16 , 32 , 64 , 128 , 256
CURSORS AND MEASUREMENT
Voltage Measurement Vpp ,Vamp ,Vavg ,Vrms ,Vhi ,Vlo ,Vmax ,Vmin ,Rise Preshoot/Overshoot ,Fall Preshoot/Overshoot
Time Measurement Freq ,Period ,Rise Time ,Fall Time ,Positive Width ,Negative Width ,Duty Cycle
Cursors Measurement Voltage difference between cursors (V) 
Time difference between cursors (T)
Auto Counter
 
Resolution : 6 digits
Accuracy: 2%
Signal Source: All available trigger source except the Video trigger mode
ADJUSTABLE PROBE COMPENSATION SIGNAL
Frequency Range 1kHz ~ 100kHz, 1kHz/STEP
Duty Cycle Range 5% ~ 95%, 5%/STEP
CONTROL PANEL FUNCTION
Autoset Adjust Vertical VOLT/DIV, Horizontal TIME/DIV, and Trigger level automatically
Save Setup Up to 15 sets of measurement conditions
Save Waveform 15 sets of waveform
DISPLAY
TFT LCD Type 5.7 inch
Display Resolution 234(Vertically) x 320(Horizontally) Dots
Display Graticule 8 x 10 divisions
Display Brightness Adjustable
INTERFACE
USB Device USB1.1 & 2.0 full speed compatible (Pictbridge Compatibility Printers Supported)
USB Host Image (BMP), waveform data (CSV), and setup (SET)
POWER SOURCE
Line Voltage Range AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection
MISCELLANEOUS
Multi-Language Menu Available
Onscreen Help Available
DIMENSIONS & WEIGHT
  310(W) x 142 (H) x 140(D)mm, Approx. 2.5kg

 