GW INSTEK GPT-9804 电气安全测试仪 (AC5KV @40mA, DC6KV@10mA, IR, GB)
制造商: GW INSTEK Model: GPT-9804 来源: China - 联系
 
<td width="111" valign="top" style="width:83.6pt;border-top:none;border-left:
| 
 AC WITHSTANDING  | 
|||
| 
 Output-Voltage Range  | 
 0.100kV~ 5.000kV ac  | 
||
| 
 Output-Voltage Resolution  | 
 2V/step  | 
||
| 
 Output-Voltage Accuracy  | 
 ± (1% of setting +5V) [no load]  | 
||
| 
 Maximum Rated Load  | 
 200 VA (5kV/40mA)  | 
||
| 
 Maximum Rated Current  | 
 40mA (0.5kV < V ≦ 5kV) 10mA (0.1kV ≦ V≦ 0.5kV)  | 
||
| 
 Output-Voltage Waveform  | 
 Sine wave  | 
||
| 
 Output-Voltage Frequency  | 
 50 Hz / 60 Hz selectable  | 
||
| 
 Voltage regulation  | 
 ± (1% of reading +5V) [full load → no load]  | 
||
| 
 Voltmeter Accuracy  | 
 ± (1% of reading+ 5V)  | 
||
| 
 Current Measurement Range  | 
 0.001mA~040.0mA  | 
||
| 
 Current Best Resolution  | 
 0.001mA / 0.01mA / 0.1mA  | 
||
| 
 AC Current Measurement Accuracy  | 
 ±(1.5% of reading +30 counts) when HISET < 1.00mA ±(1.5% of reading +3 counts) when HISET ≧ 1.00mA  | 
||
| 
 Window Comparator Method  | 
 Yes  | 
||
| 
 ARC Detect  | 
 Yes  | 
||
| 
 RAMP (Ramp-Up Time)  | 
 0.1~999.9s  | 
||
| 
 TIMER (Test Time)*  | 
 OFF, 0.5s~999.9s  | 
||
| 
 GND  | 
 ON/OFF  | 
||
| 
 DC WITHSTANDING  | 
|||
| 
 Output-Voltage Range  | 
 0.100kV~ 6.000kV dc  | 
||
| 
 Output-Voltage Resolution  | 
 2V/step  | 
||
| 
 Output-Voltage Accuracy  | 
 ± (1% of setting +5V) [no load]  | 
||
| 
 Maximum Rated Load  | 
 50W (5kV/10mA)  | 
||
| 
 Maximum Rated Current  | 
 10mA (0.5kV < V ≦ 6kV) 2mA (0.1kV ≦ V≦ 0.5kV)  | 
||
| 
 Voltage regulation  | 
 ± (1% of reading +5V) [full load → no load]  | 
||
| 
 Voltmeter Accuracy  | 
 ± (1% of reading+ 5V)  | 
||
| 
 Current Measurement Range  | 
 0.001mA~010.0mA  | 
||
| 
 Current Best Resolution  | 
 0.001mA / 0.01mA / 0.1mA  | 
||
| 
 DC Current Measurement Accuracy  | 
 ±(1.5% of reading +30 counts) when HISET < 1.00mA ±(1.5% of reading +3 counts) when HISET ≧ 1.00mA  | 
||
| 
 Window Comparator Method  | 
 Yes  | 
||
| 
 ARC Detect  | 
 Yes  | 
||
| 
 RAMP (Ramp-Up Time)  | 
 0.1~999.9s  | 
||
| 
 TIMER (Test Time)*  | 
 OFF, 0.5s~999.9s  | 
||
| 
 GND  | 
 ON/OFF  | 
||
| 
 INSULATION RESISITANCE  | 
|||
| 
 Output-Voltage  | 
 50V~1000V dc  | 
||
| 
 Output-Voltage Resolution  | 
 50V/step  | 
||
| 
 Output-Voltage Accuracy  | 
 ± (1% of setting +5V) [no load]  | 
||
| 
 Resistance Measurement Range  | 
 1MW~ 9500MW  | 
||
| 
 
  | 
 Test voltage  | 
 Measurable Range  | 
 Accuracy  | 
| 
 
  | 
 50V≦V≦450V  | 
 1MW~ 50MW 51MW~ 2000MW  | 
 ±(5% of reading +1 count) ±(10% of reading +1 counts)  | 
<td width="335" valign="top" colspan="2" style="width:250.9pt;border-top:none;
| 
 AC WITHSTANDING  | 
|||
| 
 Output-Voltage Range  | 
 0.100kV~ 5.000kV ac  | 
||
| 
 Output-Voltage Resolution  | 
 2V/step  | 
||
| 
 Output-Voltage Accuracy  | 
 ± (1% of setting +5V) [no load]  | 
||
| 
 Maximum Rated Load  | 
 200 VA (5kV/40mA)  | 
||
| 
 Maximum Rated Current  | 
 40mA (0.5kV < V ≦ 5kV) 10mA (0.1kV ≦ V≦ 0.5kV)  | 
||
| 
 Output-Voltage Waveform  | 
 Sine wave  | 
||
| 
 Output-Voltage Frequency  | 
 50 Hz / 60 Hz selectable  | 
||
| 
 Voltage regulation  | 
 ± (1% of reading +5V) [full load → no load]  | 
||
| 
 Voltmeter Accuracy  | 
 ± (1% of reading+ 5V)  | 
||
| 
 Current Measurement Range  | 
 0.001mA~040.0mA  | 
||
| 
 Current Best Resolution  | 
 0.001mA / 0.01mA / 0.1mA  | 
||
| 
 AC Current Measurement Accuracy  | 
 ±(1.5% of reading +30 counts) when HISET < 1.00mA ±(1.5% of reading +3 counts) when HISET ≧ 1.00mA  | 
||
| 
 Window Comparator Method  | 
 Yes  | 
||
| 
 ARC Detect  | 
 Yes  | 
||
| 
 RAMP (Ramp-Up Time)  | 
 0.1~999.9s  | 
||
| 
 TIMER (Test Time)*  | 
 OFF, 0.5s~999.9s  | 
||
| 
 GND  | 
 ON/OFF  | 
||
| 
 DC WITHSTANDING  | 
|||
| 
 Output-Voltage Range  | 
 0.100kV~ 6.000kV dc  | 
||
| 
 Output-Voltage Resolution  | 
 2V/step  | 
||
| 
 Output-Voltage Accuracy  | 
 ± (1% of setting +5V) [no load]  | 
||
| 
 Maximum Rated Load  | 
 50W (5kV/10mA)  | 
||
| 
 Maximum Rated Current  | 
 10mA (0.5kV < V ≦ 6kV) 2mA (0.1kV ≦ V≦ 0.5kV)  | 
||
| 
 Voltage regulation  | 
 ± (1% of reading +5V) [full load → no load]  | 
||
| 
 Voltmeter Accuracy  | 
 ± (1% of reading+ 5V)  | 
||
| 
 Current Measurement Range  | 
 0.001mA~010.0mA  | 
||
| 
 Current Best Resolution  | 
 0.001mA / 0.01mA / 0.1mA  | 
||
| 
 DC Current Measurement Accuracy  | 
 ±(1.5% of reading +30 counts) when HISET < 1.00mA ±(1.5% of reading +3 counts) when HISET ≧ 1.00mA  | 
||
| 
 Window Comparator Method  | 
 Yes  | 
||
| 
 ARC Detect  | 
 Yes  | 
||
| 
 RAMP (Ramp-Up Time)  | 
 0.1~999.9s  | 
||
| 
 TIMER (Test Time)*  | 
 OFF, 0.5s~999.9s  | 
||
| 
 GND  | 
 ON/OFF  | 
||
| 
 INSULATION RESISITANCE  | 
|||
| 
 Output-Voltage  | 
|||