HT HT4011 clamp meter (AC 400A; true RMS)

DC Voltage (Autorange) 

400.0mV; (0.8%rdg + 2dgt); 10M 600VDC/ACrms  

4.000V/ 40.00V; (1.5%rdg + 2dgt); 10M 600VDC/ACrms     

400.0V/ 600.0V; (2.0%rdg + 2dgt); 10M 600VDC/ACrms   

AC Voltage (Autorange)

4.000V/ 40.00V/ 400.0V; (1.8%rdg + 8dgt); 10M; 50  400Hz; 600VDC/ACrms 

600V; (2.5%rdg + 8dgt); 10M; 50  400Hz; 600VDC/ACrms  

Resistance and Continuity test (Autorange)

400.0/ 4.000k/ 40.00k/ 400.0k/ 4.000M; (1.0%rdg + 5dgt); ≤ 60; 600VDC/ACrms

40.00M; (2.0%rdg + 10dgt); ≤ 60; 600VDC/ACrms 

AC Current 

 40.00A; (2.5%rdg + 8dgt); 50  60Hz; 400Arms 

400.0A; (2.8%rdg + 8dgt); 50  60Hz; 400Arms  

Capacitance (Autorange) 

40.00nF; (4.0%rdg + 20dgt); 600VDC/ACrms 

400.0nF/ 4.000F; (3.0%rdg + 5dgt); 600VDC/ACrms  

40.00F/ 400.0F; (4.0%rdg + 10dgt); 600VDC/ACrms  

Diode test: 0.3mA typical; 1.5VDC 

Frequency with test leads (Autorange)  : 10.00Hz  49.99Hz/ 50.0Hz  499.9Hz/ 0.500kHz  4.999kHz/ 5.00kHz  10.0kHz; (1.5%rdg + 2dgt); >15Vrms; 600VDC/ACrms 

Duty Cycle (Autorange): 0.5%  99.0%; (1.2%rdg + 2dgt) 

Temperature with type K probe (Autorange) : 

-20.0399.0°C/ 400  760°C; (3.0%rdg + 5°C); 600VDC/ACrms 

-4.0  750.0°F/ 752  1400°F; (3.0%rdg + 9°F); 600VDC/ACrms  

Size (L x W x H): 200 x 66 x 37mm

Weight (including battery): 205g

Max conductor size: 30mm

Battery: 2x1.5V batteries type AAA LR03

Auto Power OFF: after 30 minutes of idleness (not disabled)

Display: 4 LCD (max 4000 counts), decimal point, unit symbol indication

Sample rate: 2 times/sec

Conversion mode: mean value 

Insulation: double insulation

Pollution level: 2


Accessories:

Carrying bag HT4011

TK101

Pair of Leads KIT4000A

Adapter T10

Batteries and user manual