DCV: 600.0mV/6.000/60.00/600.0/1000V
ACV[RMS]: 600.0mV/6.000/60.00/600.0/1000V
DCA: 600.0/6000μA/60.00/440.0mA/6.000/10.00A
ACA [RMS]: 600.0/6000μA/60.00/440.0mA/6.000/10.00A
Ω: 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
Continuously monitored: 600.0Ω
Checkdiode: 2V
C: 10.00/100.0nF/1.000/10.00/100.0/1000μF
F: 10.00~~9.999/9.00999.9Hz/0.90099.99/90.0~~99.99kHz
Temperature: -50~ 600ºC(withK-typeTemperatureprobe)
Other Features: DataHold (D/H),AutoHold(A /H), RangeHold (R/H)...
Source: R6P(1.5V)× 4
Size: 192 (L)×90 (W)×49 (D)mm
Weight: 560g
Accessories: Battery,probe,Manuals
Details
High Accuracy, High Performance and Reliable Measurements |
• |
0.09% basic DC accuracy |
• |
Large display with 6,000 counts |
• |
True-RMS Measurements |
• |
True-RMS or MEAN value detection mode can be selected * |
• |
Low-pass filter for motor drive measurements |
• |
User calibration function |
|
Safety design for industrial use |
• |
Complies with IEC 61010-1 CAT.IV 600V, CAT.III 1000V |
• |
Terminal shutter to prevent incorrect insertion of test leads in current terminals |
• |
Very wide operating temperature range from -10 to 55ºC |
|
(Photo: 1052) |
|
Reliable support for data management * |
• |
Large data internal memory * |
|
|
KEW 1052: 1,600 data (logging), 100 data (manual) |
• |
Download data and Live Monitoring on a PC via the USB interface (Option for USB Communication set) * |
|
* Only for KEW 1052 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
KEW 1051 |
|
|
|
KEW 1052 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Detection mode |
|
|
|
RMS |
|
|
|
MEAN/RMS (switch) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DC V |
|
|
|
600.0mV/6.000/60.00/600.0/1000V (Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V]) |±0.09%rdg±2dgt (Basic accuracy) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AC V [RMS] |
|
|
|
600.0mV/6.000/60.00/600.0/1000V (Input impedance: 10MΩ<200pf 600mv="" 11m="" 50pf="" 6v="" br=""> 10MΩ<50pf 60="" 600="" 1000v="" span=""> |±0.5%rdg±5dgt (Basic accuracy) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DC A |
|
|
|
600.0/6000µA/60.00/440.0mA/6.000/10.00A |±0.2%rdg±2dgt (Basic accuracy) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AC A [RMS] |
|
|
|
600.0/6000µA/60.00/440.0mA/6.000/10.00A |±0.75%rdg±5dgt (Basic accuracy) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ω |
|
|
|
600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ |±0.4%rdg±1dgt (Basic accuracy) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Continuity buzzer |
|
|
|
600.0Ω (The buzzer turns on for resistances lower than 50±30Ω) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Diode test |
|
|
|
2.000V|±1%rdg±2dgt Open curcuit voltage: <3.5v approx="" 0="" 5ma="" measuring="" current="" td=""> |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Capacitance |
|
|
|
10.00/100.0nF/1.000/10.00/100.0/1000µF |±2%rdg±5dgt (Basic accuracy) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequency |
|
|
|
10.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz |±0.02%rdg±1dgt (Basic accuracy) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Temperature |
|
|
|
-50~600ºC|±2%rdg±2ºC (with the use of K-type Temperature probe) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Other functions |
|
|
|
Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H), Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *, LCD backlight |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Withstand voltage |
|
|
|
6,880V/5 sec. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Applicable standards |
|
|
|
IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2, IEC 61010-031, IEC 61326-1 (EMC) |
|
|
|
|
|
|
|
|
|
|