For full functionality of this site it is necessary to enable JavaScript.

Teledyne LeCroy WaveAce 234示波器(300 MHz,1 GS / s,4通道)


Vertical System

Bandwidth300 MHz
Rise time1.2 ns
Input Channels4
Bandwidth Limiters20 MHz
Input Impedance1 MΩ ± 2% || 13 pF ± 3 pF, 50 Ω ± 2%
Input CouplingAC, DC, GND
Maximum Input Voltage1 MΩ: ± 400 Vpk, 50 Ω: 5 VRMS
Channel-Channel Isolation≥ 100:1 at 150 MHz
Vertical Resolution8 bits
Sensitivity2 mV/div - 5 V/div
DC Gain Accuracy±3%: 5 mV/div - 5 V/div (fixed gain ranges)
±4%: 2mV/div and variable gain ranges
Offset Range±800 mV: 2mV/div - 100 mV/div
±40V: 102 mV/div - 5 V/div
 

Horizontal System

Time/Division Range1 ns/div - 50 s/div
Clock Accuracy100 ppm
Trigger and Interpolator Jitter.4 ns (pk-pk)
 

Acquisition System

Single-Shot Sample Rate/Ch2 GS/s on 1 Ch
1 GS/s on 2 Ch
Equivalent Sample Rate50 GS/s
Memory20 kpts/Ch on 1 Ch
10 kpts/ch on 2 Ch
 

Acquisition Modes

AveragingSelectable Number of Sweeps:
4, 16, 32, 64, 128, 256
Peak Detect2.5 ns
InterpolationLinear, Sin x/x
Enhanced Resolutionna
Sequence Modena
 

Triggering System

ModesNormal, Auto, Single, Stop
SourcesCh 1 - Ch 4, EXT, EXT/5, AC Line
Coupling ModeAC, DC, LF Rej, HF Rej,
Pre-trigger Delaymemory/(2 * sample rate)
Post-trigger Delay260 Divisions
Hold-off by Time or Events100 ns - 1.5 s
Internal Trigger Range±6 divisions from center
Trigger Sensitivity1 division: DC - 10 MHz
1.5 divisions: 10 MHz - 300 MHz
External Trigger SensitivityExt: 200 mVpp from DC to 10 MHz
300 mVpp from 10 MHz to 300 MHz
Ext/5: 1Vpp from DC to 10 MHz
1.5 mVpp from 10 MHz to 300 MHz
External Trigger Input RangeExt: ±1.2 V, EXT/5: ±6 V
 

Display

TypeColor 5.7" TFT-LCD
ResolutionQVGA; 320 x 234 pixels
Grid StylesYT (12 horizontal divisions), XY
 

Trigger Types

Optional Advanced Triggersna
Optional Serial Data Triggersna
 

Internal Storage

Waveform Storage20 waveforms and 2 reference waveforms
Setup Storage20 setups
 

Math

Number of Math Traces1
Standard Math FunctionsAdd, Subtract, Multiply, Divide, FFT
Optional Math Functionsna
 

Measurements

Number of Measurements Displayed5
Measurement ParametersAmplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling
 

Probes

ProbesQty. (4) ÷10/1 Passive Probes
Scale FactorsManual: ÷1, ÷10, ÷100, ÷1000
Calibration Output1 kHz square wave, 3Vp-p (typical), output to probe hook
 

Interface

GPIB Port (optional)na
USB (Device)1
Ethernet Port1
USB (Host)2
Serial Portna
 

Power Requirements

Voltage100 - 240 VAC, 45 Hz to 440 Hz
Max. Power Consumption50 VA
 

Environmental and Safety

Temperature (Operating)10 °C to 40 °C
Temperature (Non-Operating)-20 °C to 60 °C
Humidity (Operating)85% RH, 40 °C
Humidity (Non-Operating)85% RH, 65 °C
Altitude (Operating)3000 m
Altitude (Non-Operating)15,266 m
 

Physical Dimensions

Dimensions (HWD)152 mm x 336 mm x 118 mm
(5.9" x 13.2" x 4.65")
Weight3.0 kg (6.6 lbs)
 

Warranty and Service

Warranty and Service3-year warranty; calibration recommended annually. Optional service programs include extended warranty and calibration services.

 

Details


  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会