For full functionality of this site it is necessary to enable JavaScript.

OWON SDS7072 Digital Oscilloscopes (70MHz, 2 Ch, 1GSa/s)

Bandwidth 70MHz
Sample rate(Real time) 1GSa/s
Horizontal Scale(S/div) 2ns/div~100s/div, step by 1~2~5
Rise time (at input, typical) ≤5ns
Channels Dual
Display 8" color LCD, TFT display , 800*600 pixels, 65535 colors
Input impedance 1MΩ±2%in parallel with 15pF±5pF
Channels Isolation 50Hz: 100 : 1, 10MHz: 40 : 1
Max. input voltage 400V (PK-PK) DC + AC PK-PK
DC gain accuracy ±3%
DC accuracy(Average) Average≥16:±(3% reading+0.05div) for ΔV
Probe attenuation factor 1X,10X,100X,1000X
LF respond(AC, -3dB) ≥5Hz(at input, AC coupling, -3dB)
Record length Max.10M points for each channel
Sampling rate/relay time accuracy ±100ppm
Interpolation (sin x)/x
Interval(ΔT) accuracy (full bandwidth) Single: ±(1 interval time+100ppm×reading+0.6ns) Average>16:±(1 interval time+100ppm×reading+0.4ns)
Input coupling DC, AC, Ground
Vertical resolution (A/D) 8 bits resolution (2 Channels simultaneously)
Vertical sensitivity 2mV/div~10V/div(at input)
Trigger type Edge, Pulse, Video, Slope, Alternate
Trigger mode Auto, Normal, Single
Trigger level ±6 divisions from screen center
Acquisition modes Sample, Peak Detect and Average
Line/field frequency(Video) Support standard NTSCPAL and SECAM broadcast systems
Cursor measurement ΔV and ΔT between cursors
Waveform Math +, -, ×, ÷, FFT
Waveform storage 15 waveforms
Communication interface USB, Support USB Flash Disk Storage, Pass/Fail
Cymometer Available
Power supply 100V-240V AC, 50/60Hz, CATII
Power consumption <18W
Fuse 1A, T class, 250V

 

Details
Bandwidth 70MHz
Sample rate(Real time) 1GSa/s
Horizontal Scale(S/div) 2ns/div~100s/div, step by 1~2~5
Rise time (at input, typical) ≤5ns
Channels Dual
Display 8" color LCD, TFT display , 800*600 pixels, 65535 colors
Input impedance 1MΩ±2%in parallel with 15pF±5pF
Channels Isolation 50Hz: 100 : 1, 10MHz: 40 : 1
Max. input voltage 400V (PK-PK) DC + AC PK-PK
DC gain accuracy ±3%
DC accuracy(Average) Average≥16:±(3% reading+0.05div) for ΔV
Probe attenuation factor 1X,10X,100X,1000X
LF respond(AC, -3dB) ≥5Hz(at input, AC coupling, -3dB)
Record length Max.10M points for each channel
Sampling rate/relay time accuracy ±100ppm
Interpolation (sin x)/x
Interval(ΔT) accuracy (full bandwidth) Single: ±(1 interval time+100ppm×reading+0.6ns) Average>16:±(1 interval time+100ppm×reading+0.4ns)
Input coupling DC, AC, Ground
Vertical resolution (A/D) 8 bits resolution (2 Channels simultaneously)
Vertical sensitivity 2mV/div~10V/div(at input)
Trigger type Edge, Pulse, Video, Slope, Alternate
Trigger mode Auto, Normal, Single
Trigger level ±6 divisions from screen center
Acquisition modes Sample, Peak Detect and Average
Line/field frequency(Video) Support standard NTSCPAL and SECAM broadcast systems
Cursor measurement ΔV and ΔT between cursors
Waveform Math +, -, ×, ÷, FFT
Waveform storage 15 waveforms
Communication interface USB, Support USB Flash Disk Storage, Pass/Fail
Cymometer Available
Power supply 100V-240V AC, 50/60Hz, CATII
Power consumption <18W
Fuse 1A, T class, 250V
  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会