- Current measurement DC A:
Measuring range; Resolution; Accuracy (of measured value)
500 μA; 0.01 μA; ± (1% + 6 digits)
5000 μA; 0.1 μA; ± (1% + 6 digits)
50 A; 0.01A; ± (2.5% + 5 digits)
1000 A; 0.1 A; ± (2.5% + 30 digits)
- Current measurement AC A:
Measuring range; Resolution; Accuracy (of measured value)
500 μA; 0.01 μA; ± (1.5% + 30 digits)
5000 μA; 0.1 μA; ± (1.5% + 30 digits)
50 A; 0.01A; ± (2.5% + 30 digits)
1000 A; 0.1 A; ± (2.8% + 30 digits)
- Resistance measurement:
Measuring range; Resolution; Accuracy (of measured value)
500 Ω; 0.01; ± (1% + 9 digits)
5 kΩ; 0.0001; ± (1% + 5 digits)
50 kΩ; 0.001; ± (1% + 5 digits)
500 kΩ; 0.01; ± (1% + 5 digits)
5 MΩ; 0.0001; ± (3% + 10 digits)
50 MΩ; 0.001; ± (3.5% + 10 digits)
- Voltage measurement DC V:
Measuring range; Resolution; Accuracy (of measured value)
500 mV; 0.01 mV; ± (0.1 % + 8 Digit)
5 V; 0.0001 V; ± (0.1 % + 4 Digit)
50 V; 0.001 V; ± (0.1 % + 4 Digit)
500 V; 0.01 V; ± (0.1 % + 4 Digit)
600 V; 0.1 V; ± (0.5 % + 4 Digit)
- Voltage measurement AC V (50 Hz ... 100 Hz):
Measuring range; Resolution; Accuracy (of measured value)
500 mV; 0.01 mV; ± ( 0.8 % + 9 Digit) (at 50 Hz / 60 Hz)
5 V; 0.0001 V; ± (1 % + 30 Digit)
50 V; 0.001 V; ± (1 % + 30 Digit)
500 V; 0.01 V; ± (1 % + 30 Digit)
600 V; 0.1 V; ± (1 % + 30 Digit)
- Capacitance measurement:
Measuring range; Resolution; Accuracy (of measured value)
500 nF; 0.01; ± (3.5% + 40 digits)
5000 nF; 0.1; ± (3.5% + 10 digits)
50 μF; 0.001; ± (3.5% + 10 digits)
500 μF; 0.01; ± (3.5% + 10 digits)
5mF; 0.0001; ± (5% + 10 digits)
- Frequency measurement:
Measuring range; Resolution; Accuracy (of measured value)
50 Hz; 0.001; ± (0.3% + 2 digits)
500 Hz; 0.01; ± (0.3% + 2 digits)
5 kHz; 0.0001; ± (0.3% + 2 digits)
50 khz; 0.001; ± (0.3% + 2 digits)
500 kHz; 0.01; ± (0.3% + 2 digits)
5 Mhz; 0.0001; ± (0.3% + 2 digits)
10 MHz; 0.001; ± (0.3% + 2 digits)
- Duty cycle:
Measuring range: 5% ... 95%
Resolution: 0.1
Accuracy (of measured value): ± (1% + 2 digits)
Pulse width: 100 μs ... 100 ms
Frequency: 10 Hz ... 10 kHz
- Temperature:
Measuring range: -100 ... 1000°C / -148 ... 1832°F
Resolution: 0.1
Accuracy (of measured value): ± (1% + 2.5°C / 3.5°F)
-General technical data:
Conductor diameter: Max. 48 mm / 1.9 in
Display: Two lines 50,000 digits
Continuity test: 50 ohms / < 50 mA
Diode test: 0.3 mA / 2.8 V DC
Battery indicator: Battery icon when battery low
Overrange: OL, if measuring range exceeded
Sample rate: 2 Hz
Peak detection: > 1 ms
Thermocouple: Type K
Fuse: 500-mA ceramic quick-acting
AC bandwidth (AC A / AC V): 50 Hz ... 400 Hz
AC measurement: True RMS
Operating conditions: 5 ... 40°C / 41 ... 104°F, max. 80% RH at 31°C / 87.8°F
Storage conditions: -20 ... 60°C / -4 ... 140°F, max. 80% RH
Power supply: 9V block battery
Automatic shutdown: After about 30 minutes
Dimensions (W x H x D): 230 x 76 x 40 mm / 9 x 3 x 1.6 in
Weight: 315 g / < 1 lb
Safety: IEC 1010-1 (2001):
EN 61010-1 (2001)
CAT III 600V
CAT II 1000V
Degree of pollution 2
Delivery scope:
1 x Clamp meter PCE-HVAC 6
1 x Transport bag
2 x Test leads
1 x Battery 9V block battery
1 x ISO Calibration Certificate