PCE PCM 3 单相钳形表 (AC 1000A)

- Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH

- Measuring function:     

Current measurement AC:     

Measuring range; Resolution; Accuracy

60 A; 0.01 A; ± 2% + 8 Dgt

600 A; 0.1 A; ± 2% + 8 Dgt

1000 A; 1 A; ± 2% + 8 Dgt     

Maximum input current: 1000 A AC

Frequency range: 40 .... 400 Hz     

- Measuring function:     

Inrush current AC:     

Measuring range; Resolution; Accuracy

60 A; 0.01 A; For reference only

600 A; 0.1 A; ± 5% + 60 Dgt

1000 A; 1 A; ± 5% + 60 Dgt     

Integral time: 100 ms  

Measuring range: 20 ... 1000 A  

Frequency range: 40 .... 400 Hz     

- Measuring function:     

Voltage measurement DC:     

Measuring range; Resolution; Accuracy

6V; 0.001V; ± 0.5% + 5 Dgt

60V; 0.01V; ± 0.5% + 5 Dgt

600V; 0.1V; ± 0.5% + 5 Dgt

1000V; 1V; ± 0.8% + 4 Dgt     

Input impedance: 10 MΩ

Maximum input voltage: 750V AC (rms value) or 1000V DC     

- Measuring function:     

Voltage measurement AC:     

Measuring range; Resolution; Accuracy

6V; 0.001V; ± 0.6% + 4 Dgt

60V; 0.01V; ± 0.6% + 4 Dgt

600V; 0.1V; ± 0.6% + 4 Dgt

1000V; 1V; ± 0.8% + 4 Dgt     

Input impedance: 10 MΩ

Maximum input voltage: 750V AC (rms value) or 1000V DC

Frequency range: 40 ... 400 Hz     

- Measuring function:     

Frequency measurement with    

The current measuring function    

Measuring range; Resolution; Accuracy

99.99 Hz; 0.01 Hz; ± 1.5% + 5 Dgt

999.9 Hz; 0.1 Hz; ± 1.5% + 5 Dgt    

Measuring range: 10 ... 1 kHz

Measuring range of the input signal: > 20 AAC (rms value)

The input current increases with the measuring frequency.

Maximum input current: 1000 AAC (rms value)    

- Measuring function:     

Frequency measurement with the    

Voltage measurement function    

Measuring range; Resolution; Accuracy

99.99 Hz; 0.01 Hz; ± 1.5% + 5 Dgt

999.9 Hz; 0.1 Hz; ± 1.5% + 5 Dgt

9,999 kHz; 0.001 kHz; ± 1.5% + 5 Dgt   

Measuring range: 10 ... 10 kHz

Measuring range of the input signal: > 1V AC (rms value)

The input current increases with the measuring frequency.

Maximum input voltage: 1000V AC (rms value)     

- Measuring function:     

Frequency measurement :     

Measuring range; Resolution; Accuracy

9,999 Hz; 0.001 Hz; ± 0.3% + 5 Dgt

99.99 Hz; 0.01 Hz; ± 0.3% + 5 Dgt

9,999 kHz; 0.1 Hz; ± 0.3% + 5 Dgt

999.9 Hz; 0.001 kHz; ± 0.3% + 5 Dgt

99.99 kHz; 0.01 kHz; ± 0.3% + 5 Dgt

999.9 kHz; 0.1 kHz; ± 0.3% + 5 Dgt

9,999 MHz; 0.001 MHz; ± 0.3% + 5 Dgt     

Overvoltage protection: 1000V DC or 750V AC (rms value)

Range of voltage input> 2V

(as the input voltage increases, so does the frequency)

- Measuring function:    

Duty cycle    

Measuring range; Resolution; Accuracy

0.1 ... 99.9%; 0.1%; ± 0.3% + 5 Dgt   

Frequency range: 10 ... 10 kHz

Voltage range: 2 ... 250V AC (rms value)

(The voltage increases with the frequency)

Duty cycle with the Current measurement function:

Frequency range: 10 ... 1 kHz

Input current: 20 ... 1000 AAC (rms value)

Duty cycle with the oltage measurement function:

Frequency range: 10 ... 1 kHz

Input current: 1 ... 750V AC (rms value)

  Input impedance: 1MΩ     

- Measuring function:    

Resistivity  

Measuring range; Resolution; Accuracy

600 Ω; 0.1 Ω; ± 0.8% + 3 Dgt

6 kΩ; 0.001 kΩ; ± 0.8% + 3 Dgt

60 kΩ; 0.01 kΩ; ± 0.8% + 3 Dgt

600 kΩ; 0.1 kΩ; ± 0.8% + 3 Dgt

6 MΩ; 0.001 MΩ; ± 2% + 5 Dgt

60 MΩ; 0.1 MΩ; ± 2% + 5 Dgt    

Measuring voltage: approx. 0.78V

Overvoltage protection: 750V DC, 1000V AC (rms value)    

- Measuring function:    

Continuity test  

Measuring range; Resolution; Accuracy

600 Ω; 0.1 Ω    

Acoustic signal at < 50 Ω

Test voltage: 1.48V

Overvoltage protection: 750V DC, 1000V AC (rms value)    

- Measuring function:    

Capacitance measurement  

Measuring range; Resolution; Accuracy

9.999 nF; 0.001 nF; ± 3% + 5 Dgt

99.99 n.f.; 0.01 nF; ± 3% + 5 Dgt

999.9 nF; 0.1 nF; ± 3% + 5 Dgt

9.999 μF; 0.001 μF; ± 3% + 5 Dgt

99.99 μF; 0.01 μF; ± 3% + 5 Dgt

999.9 μF; 0.1 μF; ± 3% + 5 Dgt

9,999mF; 0.001 mF; ± 3% + 5 Dgt

99.99 mF; 0.01 mF; ± 3% + 5 Dgt    

Overvoltage protection: 750V DC, 1000V AC (rms value)    

- Measuring function:     

Diode measurement   

Measuring range; Resolution; Accuracy

3V ; 0.001V; -     

DC anode side: approx. 1-mA

DC cathode side: approx. 3.2V

Overvoltage protection: 750V DC, 1000V AC (rms value)     

- Measuring function:    

Single phase power measurement   

Measuring range; Resolution; Accuracy

3 W / VA / Var; 0.01 W / VA / Var; ± 3% + 5 Dgt

100 W / VA / Var; 0.1 W / VA / Var; ± 3% + 5 Dgt

4000 W / VA / Var; 1 W / VA / Var; ± 3% + 5 Dgt

10 kW / VA / var; 0.01 kW / VA / Var; ± 3% + 5 Dgt

100 kW / VA / var; 0.1 kW / VA / Var; ± 3% + 5 Dgt

750 kW / VA / var; 1 kW / VA / Var; ± 3% + 5 Dgt    

Smallest measuring current: 1-mA

Smallest measuring voltage: 1V    

- Measuring function:    

Power factor capacitive / inductive  

Measuring range; Resolution; Accuracy

0.1 ... 1; 0.001; ± 5% + 5 Dgt     

Smallest measuring current: 1-mA

Smallest measuring voltage: 1V     

- Measuring function:    

Harmonics measurement  

Measuring range; Accuracy

1; ± 3% + 10 Dgt

2 ... 6; ± 3.5% + 10 Dgt

7 ... 8; ± 4.5% + 10 Dgt

9 ... 10; ± 5% + 10 Dgt

11 ... 15; ± 7% + 10 Dgt

16 ... 20; ± 10% + 10 Dgt    

Smallest measuring current: 1-mA

Smallest measuring voltage: 1V

The resolution depends on the voltage measuring range    

- General specifications:     

Measuring range: Automatically and manually adjustable

Maximum voltage range: 1000V DC or 750V AC

Maximum working height: 2000 m / 6561 ft

Display: LCD

Maximum display: 5999 Dgt.

Overrange: "OIL"

Measuring range underflow: "-OL"

Measuring rate: 3 Hz

Automatic shutdown: After 30 minutes

Power supply: 9V block battery

Battery indicator: Icon if the battery voltage is too low

Temperature coefficient: 0.1 x accuracy x °C / °F*

Operating conditions: 0 ... 40°C, 32 ... 104°F

Storage conditions: -10 ... 60°C, 14 ... 140°F

Dimensions: 238 x 92 x 50 mm / 9.4 x 3.6 x 2 in  

Weight: About 420 g / < 1 lb (with batteries)

Delivery scope:

1 x Voltmeter PCE-PCM 3

1 x Transport bag

1 x Test lead set

1 x 9V block battery

1 x User manual