- Detector: gamma CsI(Tl)
- Sensitivity:
+ for 137Сs, no less 100 (s-1)/(μSv/h) (1.0 (s-1)/(μR/h))
+nfor 241Am, no less 200 (s-1)/(μSv/h) (2.0 (s-1)/(μR/h))
- Energy range: gamma 0.033 – 3.0 MeV
- Dose Rate: gamma 0.01 – 99.99 μSv/h (1 – 9999 μR/h)
- Dose: X
- Accuracy: ±30% (in range 0.1 – 70 μSv/h (10 – 7000 μR/h) ) (at 137Cs)
- Response time: 0.25 s
- Radionuclide identification using Bluetooth communication with external Pocket PC or smartphone:
+ Special nuclear materials (SNM): X
+ Medical radionuclides : X
+ Naturally occurring radioactive materials (NORM) : X
+ Industrial radionuclides: X
- Standards compliance: ITRAP/IAEA requirements, ANSI N42.32, ANSI N42.33(1), IEC 62401
- Alarm type: visual, audio, vibration
- Data recording: 1000
- Environmental protection: IP65
- Drop test on concrete floor: 1.5 m (4.9 ft) 0.7 m (2.3 ft) without cover
- Power supply: one AA battery
- Battery life time: up to 1000 hours
- Operating temperature: -30°C to 50°C (-22°F to 122°F)
- Size (without cover): 72 x 32 x 87 mm (2 7/8 x 1¼ x 3 3/8)
- Weight :(without cover) 180 g (6.35 oz); (with cover) 220g (7.75 oz)
- Low battery warning: LCD
- Overload indication: gamma OL
- PC Communication: IRDA