Promax IC-002 反射计功率计/ RF / 便携式/ 模拟 (1GHz / 500W)

Power ranges: 5, 15, 50, 150, 500 W, full scale (150 maximum from 800 to 1000 MHz)

Frequency range: From 25 to 1000 MHz

Correction accuracy

From 25 to 100 MHz: ±7 of full scale, using correction chart

From 100 to 510 MHz: ±6 of full scale, no correction required

From 510 to 1000 MHz: ±7 of full scale, no correction required

Insertion loss

From 25 to 512 MHz: 0.10 dB max.

From 512 to 1000 MHz: 0.15 dB max.

VSWR

From 25 to 510 MHz: 1.08 max.

From 512 to 1000 MHz: 1.12 max.

Element Broadband (from 25 to 1000 MHz, 500 W max.), rotable for forward

and reflected power measurements, non-removable

Dimensions: 127 (W.) x 185 (H.) x 102 (D.) mm

Weight: 1.8 kg

Connectors: “Quick Match” standard N female Type (BNC, UHF, TNC male of female optional)