Pulsar measurement dBi-M3 Modbus Intelligent Transducer (125 mm - 3 m (4.9 in - 9.8 ft))

Sensor Body Dimensions: 77 mm D x 134 mm H (3 in x 5.3 in) 

Weight: 1 kg (2.2 lb)

Measurement range: 125 mm to 3 m (4.9 in to 9.8 ft)

Beam Angle: <10°

Effective Beam Angle (using DATEM): 3°

Accuracy: 2 mm (0.08 in)

Resolution: 1 mm (0.04 in)

Sensor Body Material: Valox 357 PBT

Cable Lengths: Standard: 5 m, 10 m, 20 m, or 30 m (16.4 ft, 32.8 ft, 65.6 ft, or 98.4 ft)

Optional up to 150 m (492.1 ft) maximum (increments of 10 m (32.8 ft) only)

Mounting Connection: 1” BSP or 1” NPT

Enclosure Protection: IP68 / NEMA 6P

Max. And Min.Temperature (Electonics): -40 °C to +80 °C (-40 °F to +176 °F), options for front thread and flange mounting

Input Voltage Range: 5-15 V DC

Output: Modbus RTU via RS-485

Current Consumption: Average 14 mA, 0.006 mAh per measurement.

Boot Time: 1 second for the first measurement

Temperature Compensation: Automatic, internal temperature sensor, ± 0.5 °C/°F

Communcations Protocol: Modbus RTU