Pulsar measurement DFS 5.1 Doppler Flow Switch

Transducer: Model SE4 Single-head 316SS ultrasonic, with 6 m (19.7 ft) shielded cable and stainless steel mounting

Operating Temperature:

(Sensor) -40 °C to 150 °C (-40 °F to 300 °F)

Electronics Enclosure: NEMA4X (IP66) polycarbonate with clear, shatterproof cover

Accuracy: ±2%, requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm.

Repeatability: ±0.1%

Power Input: 100-240 V AC 50-60 Hz (see Popular Options), 10 VA max depending on options

Control Relays: 5 A DPDT

Set Points: ON/OFF adjustment from 0.076 m/s to 3 m/s (0.25 ft/s to 9.8 ft/s)

Operating Temp.

(Electronics): -23 °C to +60 °C (-10 °F to +140 °F)

Pipe Size: Any pipe ID from 12.7 mm to 4.6 m (0.5 in to 15 ft)

Approximate Shipping

Weight: 3.6 kg (8 lb)

Approvals: CE, cCSAus