For full functionality of this site it is necessary to enable JavaScript.

SCHNEIDER MGA 1033 磁场发生器 - 分析仪 (250 kHz, 20A)

Analyzer

Voltage input

Frequency range: DC - 250 kHz

Input impedance: 1 MΩ / 50 Ω switchable

Connector XLR, unbalanced

Max. input voltage: 100 V continuous (attenuator autoset at overvoltage); 10 V at 50 Ω in -20/0/20/40 dB

Preamplifier: 0/20 dB ADC amplifier

Current input

Frequency range: DC - 250 kHz

Shunts: 10 mΩ / 1 Ω / 100 Ω

Max. input current: 20 A continuous (overload protection)

1 Ω and 100 Ω shunt are protected additionally by an 1.5 A fuse

Connector: 4 mm safety jack (+, -)

Measurement range: 20 A, 10 A, 1 A, 100 mA, 10 mA, 1 mA

AD-converter

Resolution: 16 Bit

Sampling rate: 1.0 MS/s

Generator

Frequency range: DC - 250 kHz

Output impedance: 50 Ω

Connector: BNC, unbalanced

Signal: sine wave / square wave / triangular / DC

Amplitude: 0 – 10V AC, -10V - +10V DC

Resolution: 12 Bit (2.5 mV)

Amplifier

Frequency range: DC – 1 MHz

Connector: 4 mm safety jacks (output) BNC, unbalanced (input)

Current: 16 Arms

Voltage: 50 Vrms / 75 VDC

Distortion (DC – 100 kHz, load ≥ 4 Ohm): < 0.10 %

Voltage amplification: 10 ± 0.1 % (± 0.01 % / °C)

General data

EUT control /Connector: 9-pin Sub-D; RS-232

Connection to computer: USB

Temperature range: 0 to 40 °C

Warm-up time: 15 min

Housing: 19“ subrack or desktop case

Mains voltage: 115 / 230 VAC ± 10%,50-60 Hz

Dimensions(W x H x D): 449 mm x 177 mm x 580 mm

Weight(shipping): approx. 40 kg (net 34 kg)

Details

Option

Loop sensor/radiating loops

Field loops are required to generate magnetic fields. Magnetic fields are measured

with sensor loops. The loops are manufactured according to the definitions in MILSTD 461 and EN 55103.

Helmholtz coil Helmholtz coils are the ideal instruments for generating homogeneous magnetic

fields. The models HCS_50/28 and HCST_50/28 generate field strengths from

1000 A/m to 1 kHz. The MGA 1033 with the optional compensation board is

required for this.

Coupling transformer A coupling transformer is used for testing for conducted immunity on power lines

according to MIL-STD-461, CS 101. Due to the high common-mode voltage on the

mains side, a differential amplifier is built into the coupling transformer, which

enables simple measurement of the coupled differential voltage.

Testing equipement

acc. To EN 55103-2

Annex B of EN 55103-2 describes various test adapters intended for immunity tests

from 50 Hz to 10 kHz.