Measureable conductor size: Max. φ40 mm
Measuring range: AC 0 to 2 Arms
Output voltage: AC 0 to 50 mVrms (25 mV/A)
Accuracy (sine wave input): Band width: ±1.0%rdg ±0.4 mV (1 kHz to 3.5 kHz)
Temperature & humidity range (guaranteed accuracy): 23 ±5°C, 85%RH or less(no ondensation)
Rated voltage between circuit and ground: AC 300 Vrms Max
Operating temperature & humidity range: 0 to 50°C, 85%RH or less (no ondensation)
Storage temperature & humidity range: -20 to 60°C, 90%RH or less (no ondensation)
Temperature coefficient: 0.05% f.s./°C (0 to 50°C)
Maximum allowable input: AC 60 Arms continuous (50/60Hz)
Influence of the conductor location: Within ±0.5% rdg (0.2 to 2 A, 45 Hz to 1 kHz)
Influence of the external magnetic field: 4 mA equivalence or less (400 A/m, 50/60Hz) ±30 ppm or less (the current value of the near conductor:100 A)
Output impedance: Approx. 47 Ω
Withstand voltage: AC 3.7 kVrms / 1 minute Between jaw and case, case and output terminal, output terminal and jaw,
Recommended calibration period: 1 year
Environmental condition: Altitude up to 2000 m, in-door use
Dimension: 70(W)×120(H)×25(D) mm (excluding projections)
Cable length: Approx.3m
Output terminal: MINI DIN 6PIN
Weight: Approx.230g