Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Two-path test peak: 30kA
Stored energy: 10 kJ
Charging voltage: 30 kV
Supply mains: AC 220V 32A
Weight: 800 kg
Item: 8/20μs current wave
Output peak: 35kA,65kA,120kA,150kA,200kA
T1 front time: 8μs±10%
T2 wave tail time: 20μs±10%
Reversed overshoot: <20%
Front oscillatory: <5%
Voltage polarity: +/-, (automatic switch)
Waveform switch: Automatic switch
Charging time: 10s~999s
Charging voltage instability: Less than 1%
External sync input: 50Hz
Trigger mode: Automatic or manual, single trigger available
Trigger malfunction rate: Less than 1%
Trigger range: 100% rated charging voltage
Phase test range: 0~360°
Operating load test: internal,0~500V,5A continuous supply
Display screen : 10inch TFT color touch screen
Measurement display resolution: Better than 3%
DUT: MOV, TVS, GDT, SPD, mains surge protection device
DUT residual voltage: <5kV
Current measurement (optional): Internal test box, Rogowski coil measurement, panel BNC output
Voltage measurement (optional): Internal test box, pure-resistance voltage divider, panel BNC output
Oscilloscope: MDO3012, optional
Insulation strength: ≤500V RMS(common port COMMON to ground reference PE)
- General data:
Power supply: AC220V±10%,50/60Hz,
Temperature: -10-+40℃
Humidity: 35%-85%RH(no condensation)
Ground resistance: No more than 0.5Ω
Structure: Open style, control and base separated
Size of test room: 5M*5M(base)+3M*5M(control)
Control table: 1.8M(width)*1.1M(height)*1M(depth)
No conductive dust, no fire or explosion danger, no corrosive metal and insulation air. Waveform of mains voltage is sine wave. The THD is <5%.
