Test Current: 2 kA ~ 50 kA, ±10%
Charging Voltage: 0.5 kV ~ 15 kV
Current Waveform:
Rise time (1.25* Tr): 8 μs, ±10%
Duration (1.18*Tw): 20 μs, ±10%
Polarity: Positive/ negative/ alternative
Source Impedance: 0.3 Ω
Repetition (time for single pulse): 5 s ~ 1000 s (The minimum time is subjected to test voltage)
Counter: 1~10000
Phase Sync.: 0° ~ 360°(45 Hz ~ 65 Hz)
Pulse Current Monitor: External, optional
Trigger Mode: Manual, Auto, External Trigger
Dimension: 19” / 35U
Weight : Approx. 150 kg
- General Parameters:
Display Screen: 5.7” TFT touch screen
Working Power: AC 110 V/220 V(±10%), 50 Hz /60 Hz
Fuse: 6 A
Max. Power: 500 W
Communication Mode: Ethernet LAN, RJ45
External Control Mode: 25-pin parallel port cable
External Trigger Input : BNC, 5 V TTL, the node is open, oscilloscope can trigger the product when internal circuit is closed.
Running Control Input: BNC, 5 V TTL
Failure Detection: The failure information will be displayed on LCD in front panel when failure occurs and interrupt the working of instrument.
Working Status Indication: LED indication and LCD display on front panel
Earthing Mode: Flat earth line
Monitor Output Mode : Standard 1 m coaxial cable
Ambient Temperature: 15 ℃ ~ 35 ℃
Relative Humidity: 45% ~ 75%
Atmospheric Pressure: 86 kPa ~ 106 kPa