Measuring range (at23℃±5℃)
Range Measuring range Resolution Measuring current
1mΩ 0.0000mΩ~1.5000mΩ 0.1μΩ 3A
10mΩ 0.000mΩ~15.000mΩ 1μΩ 1A
100mΩ 0.00mΩ~150.00mΩ 10μΩ 1A
1Ω 0.0000Ω~1.5000Ω 100μΩ 100mA
10Ω 0.000Ω~15.000Ω 1mΩ 100mA
100Ω 0.00Ω~150.00Ω 10mΩ 10mA
1kΩ 0.0Ω~ 1.5000kΩ 100mΩ 1mA
% 0.5mΩ~1kΩ/±50.00% 0.01% [50nΩ] refer to the above
Accuracy [Slow] within
±(0.01%rdg+1μΩ)
±3digit [Average]
±4digit [Slow]
±5digit [Fast]
Open-circuit voltage of measuring terminal: about 4V
Measuring method: 4-terminal measurement [contact check available]
Sampling time:
[Free running mode] 2~10 times per second
[Remote start mode] about 16.5msec./ 29.8msec.
Setting range for comparator: Upper limit, lower limit for both [0~15000],
% range:50.00% [low:0~-50.00%, high:0~+50.00%]
Indication of comparator's comparison result: LED indication LO/GO/HI and buzzer
Control signal
Remote start input:"L" [OV] →"H" [DC12V] start
Remote hold input:Open and "H" [DC12V]:Free run / "L" [OV]:Hold
Comparison output [LO/GO/HI]:open collector:max.40V, 100mA
Contact error output [CE]:open collector:max.40V, 100mA
End of comparison output [EOC]:open collector:max.40V, 100mA
Operation condition: [Temp.] +5℃~+40℃ [Humidity] less than 85%
Power supply: AC100V~240V selectable, 50/60Hz, about 60VA
Outer dimension: about 333 (W) ×99 (H) ×300 (D) mm (excluding protruding parts such as rubber legs, etc.)
Weight: about 3.8kg