Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Measuring range (at23℃±5℃)
Range Measuring range Resolution Measuring current
1mΩ 0.0000mΩ~1.5000mΩ 0.1μΩ 3A
10mΩ 0.000mΩ~15.000mΩ 1μΩ 1A
100mΩ 0.00mΩ~150.00mΩ 10μΩ 1A
1Ω 0.0000Ω~1.5000Ω 100μΩ 100mA
10Ω 0.000Ω~15.000Ω 1mΩ 100mA
100Ω 0.00Ω~150.00Ω 10mΩ 10mA
1kΩ 0.0Ω~ 1.5000Ω 100mΩ 1mA
% 0.5mΩ~1.4000kΩ/±50.00% 0.01% [50nΩ] refer to the above
R measurement accuracy
±(0.01%rdg+1μQ)
±α digits
α: Average(SLOW)=3
Average(FAST)=4
SLOW=4
FAST=6
Open-circuit voltage of measuring terminal: about 9V
Measuring method: 4-terminal measurement [contact check]
Sampling time:
[Free running] 2~10 times per second
[Remote start] about 18.8msec./ 32.0msec. (60Hz)
Setting range for comparator: Upper limit, lower limit [0~15000],
% range:50.00% [low:0~-50.00%, high:0~+50.00%]
Indication of comparator's comparison result: LO/LLG/LG/GO/HG/HHG/HI LED display and buzzer
Control signal: Remote start input:"L" [OV] →"H" [DC12V] start
Remote hold input:Open and "H" [DC12V]:Free run / "L" [OV]:Hold
Comparison output [LO/GO/HI]:open collector:max.40V, 100mA
Contact error output [CE]:open collector:max.40V, 100mA
End of comparison output [EOC]:open collector:max.40V, 100mA
Operation condition: [Temp.] +5℃~+40℃ [Humidity] less than 85%
Power supply: AC100V~240V selectable, 50/60Hz, about 60VA
Outer dimension: about 333 (W) ×99 (H) ×300 (D) mm (excluding protruding parts such as rubber legs, etc.)
Weight: about 3.8kg





