- Temperature Range: 100 ~ 1200°C (212 and 2192°F)
- Optics: a (Measuring distance) = 1200 mm
- Spectral Range: 5.14 μm
- Resolution: 0.1°C
- Measurement Uncertainty (e = 1, t90 = 1 s, Tamb. = 25°C): 1% of reading in °C + 1°C
- Repeatability (e = 1, t90 = 1 s, Tamb. = 25°C): 0.5% of reading in °C + 1°C
- Emissivity ε: 0.2 ~ 1.0 adjustable via service interface
Communication and Inteface
- Analog Output: 4 ~ 20 mA, linear
- Response Time t90: 120 ms, adjustable up to 10 s via service interface
- Parameters: Sub range, emissivity, response time
- Aperture: 15 mm
Electrical
- Power Supply: 24 VDC ± 25%, ripple 500 mV
- Power Consumption: Max 0.6 W
- Load: Max 700 Ω @ 24 V
Environmental
- Protection Class: IP 65 (DIN 40 050)
- Ambient Temperature: 0 ~ 70°C (32 ~ 158°F)
- Storage Temperature: -20 ~ 70°C (-4 ~ 158°F)
- Weight: ≈450 g (≈0.992 lb)
- CE Label: According to EU directives about electromagnetical immunity
- Scope of Delivery: Instrument with selected optic, works certificate, operation manual.