Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

- Temperature Range: 600 ~ 3000°C
- Optics:
3 focusable optics:
275 ~ 520 mm
385 ~ 1125 mm
540 ~ 9000 mm
- Spectral Ranges: 940 nm
- Resolution:
Up to 1000°C: 0.01°C on interface and display;
Above 1000°C: 0.1°C on display, 0.01°C on digital interface < 0.025% of temperature range at the analog output
- Measurement Uncertainty (ε = 1, t90 = 1 s, Tamb = 23°C):
< 1500°C: 0.15% of measured value in °C + 1°C
≥ 1500°C: 0.25% of measured value in °C
≥ 2700°C: 0.35% of measured value in °C
- Repeatability (ε = 1, t90 = 1 s, Tamb = 23°C): 1°C
- Emissivity ε: 0.100 ~ 1.000 in 1⁄1000 steps
Electrical:
- Power Supply: 24 VDC (15 ~ 40 VDC), or 24 VAC (12 ~ 30 VAC), 48 ~ 62 Hz
- Power Consumption: Max 14 W
Environmental
- Protection system: IP65 (according to DIN 40 050)
- Ambient Temperature: 0 ~ 60°C (32 ~ 140°F) at the housing
- Storage Temperature: -20 ~ 70°C (-4 ~ 158°F)
- Weight: 2.2 kg (≈2.20 lbs)
- CE Label: According to EU directives about electromagnetical immunity
Interface:
- Display: Built-in 5 digit LED display, additional function LEDs
- Control Panel: 4 keys, operate with tip of ball-point pen
- Sighting: Viewfinder, laser targeting light
Communication:
- Analog Output: Linear 0 ~ 20 mA or 4 ~ 20 mA, DC, switchable; load max. 500 Ohm
- Test Current Output: Fixed 10 mA
- Serial Interface: Switchable at the pyrometer: RS232 or RS485 (addressable), half duplex; baud rate 2.4 up to 115 kBd
- Scope of Delivery: Instrument with one optics, case, power supply (service unit) NG 0S (100 ~ 240 VAC, 50 ~ 60 Hz ⇒ 24 VDC, 1 A) with 5 m connection cable to the pyrometer, PC analysing software InfraWin, work certificate according to ITS 90 (IS 12-TSP, 600 to 3000°C: work certificate up to 2500°C), user manual