- Temperature Range: 700 ~ 1800°C (1292 ~ 3272°F) (MB 18)
- Spectral Ranges:
Channel 1: 0.9 μm
Channel 2: 1.05 μm
- Resolution:
0.1°C or 0.2°F at interface
<0.0015% of selected sub range at analog output, min. 0.1°C, 16 bit; 1°C or 1°F on display
- Emissivity ε: 0.050 ~ 1.000 in steps of 1/1000 (1-color mode)
- Transmittance τ: 0.050 ~ 1.000 in steps of 1/1000 (1-color mode)
- Emissivity Slope κ: 0.800 ~ 1.200 in steps of 1/1000 (2-color mode)
- Measurement Uncertainty (κ = 1, t90 = 1 S, Tamb. = 25°C):
< 1500°C: 0.3% of reading in °C + 2°C
> 1500°C: 0.6% of reading in °C
- Repeatability (κ = 1, t90 = 1 S, Tamb. = 25 °C): 0.15% of reading in °C + 1°C
Optical Specifications:
- Sighting: Thermal image with marked pyrometer spot
- Optics: Manually focusable from rear cover measuring distance a = 210 ~ 5000 mm
- Distance Ratio: Approx. 190 : 1
Electrical:
- Power Supply: 24 VDC ±25%, ripple must be less than 50 mV
- Power Consumption: Approximately 8.5 W
- Load (analog output): 0 ~ 500 Ω
Environmental
- Protection Class: IP 65 IEC 60529 (value in mated condition)
- Ambient Temperature: 0 ~ 60°C (0 ~ 140°F)at housing
- Storage Temperature: -20 ~ 80°C (-4 ~ 176°F)
- Weight: 0.755 kg (≈1.66 lbs)
- Housing: Stainless steel
- CE Label: According to EU directives about electromagnetical immunity
Interface:
- Connection: 12-pin connector
- Display (in rear cover): LED, 4 digit matrix, 5 mm high-temperature signal or measuring distance
Communication
- Analog Output: Adjustable 0 ~ 20 mA or 4 ~ 20 mA, linear (via digital interface)
- Digital Interface: RS485 addressable (half-duplex)
Baud rate: 1200 Bd to 115.2 kBd (on request RS232, not addressable)
- Response Time t90: <2 ms (with dynamic adaption at low signal levels); adjustable to min, 0.01 s, 0.05 s, 0.25 s, 1 s, 3 s, 10 s
- Video Cable: 10 m
- Scope of Delivery: Pyrometer, video gabber, video cable, PC adjustment and evaluation software InfraWin, works certificate, and operating instructions.