Electrical
- Source Voltage: 180 ~ 230 VAC (208 VAC nominal); 3φ with ground (no neutral)
- Efficiency: 85% at full-rated output
- Output Frequency: 40 kHz ±0.01%
- Output Power: 10 kW
- Output Voltage: 547 VRMS nominal in tap 4; 953 VRMS max in tap 7
- Output Current: 18 ARMS nominal in tap 4; 32 ARMS max in tap 1
- Output Load 42 Ω dual floating outputs nominal in tap 4
- Regulation Modes: Power, voltage, and current
- Measurement Accuracy: ±1%
- Ambient Temperature: 0 ~ 40°C (32 ~ 104°F)
- Relative Humidity: 15% ~ 85%, non-condensing
Cooling
- Cooling Medium: Water
- Temperature: 5 ~ 30°C (41 ~ 86°F) to inlet temperature
- Flow: 7.57 lpm (2 gpm) min
- Pressure: 6.9 bars (100 psi) max
- Dimension: 177 mm (H) x 482.6 mm (W) x 495.3 mm (D); 6.97" (H) x 19" (W) x 19.5" (D)
- Weight: 40.8 kg (90 lb) max