- Temperature Range: 650 ~ 1300°C
- Spectral Range: 383 ~ 410 nm (10% of values)
- Latency Time Between 2 Measurements: < 1 μs
- Resolution:
0.1°C at interface
< 0.025% of the set partial measurement range at the analog output (12 bits)
- Emissivity ε: 0.100 ~ 1.000 in steps of 1/1000
- Measurement Uncertainty (ε = 1, t90 = 1 s, Thous. = 28°C):
< 1000°C: 3°C
> 1000°C: 0.3% oR
- Repeatability (ε = 1, t90 = 1 s, Thous. = 28°C): 0.1% oR + 0.1°C
Electrical:
- Power Consumption: Max 5 W
- Load (analog output): 0 ~ 500 Ω
Environmental:
- Operating Temperature: 10 ~ 38°C on the housing
- Storage Temperature: -20 ~ 50°C
Interface and Communication:
- Analog Output: 0 ~ 20 mA or 4 ~ 20 mA, linear (via digital interface)
- Digital Interface:
RS485 addressable (half-duplex)
Baud rate: 1200 to 38400
- Exposure Time t90: Integration time: min of 8 ms
- Optic: Fixed optics
- Field of View: min 8:1 (9.8 mm)