Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Sensor specifications
Particulate Matter (PMo & PM25)
Range: 0.000 to 1.000 mg/m3
Sensor type: LPC
Minimum detection limit: 0.001 mg/m3
Accuracy of factor calibration: ± (0.002 mg/m3 + 15% of reading)
Resolution: 0.001 mg/m3
Response time: 5 seconds
Temperature: 0 to 40°C
Relative Humidity: 0 to 90%
Carbon Dioxide (CO2)
Range: 0 -5000 ppm
Sensor type: NDIR
Minimum detection limit: 20 ppm
Accuracy of factor calibration: <±20 ppm + 5%
Resolution: 1 ppm
Response time: 120 seconds
Temperature: 0 to 40°C
Relative Humidity: 15 to 90%
VOC
Range: 0 - 25 ppm
Sensor type: GSS
Minimum detection limit: 0.1 ppm
Accuracy of factor calibration: <± 0.1 ppm + 10%
Resolution: 0.1 ppm
Response time: 60 seconds
Temperature: 0 to 40°C
Relative Humidity: 15 to 90%
Monitor specifications
Measurement units: Gas: ppm or mg/m3 | Humidity: % | Temperature °C or °F
Reading functions: Instant, minimum, maximum, average
Sensor head: Active fan sampling to ensure high accuracy measurements, interchangeable, replaceable
Sensor calibration: Zero and gain calibration in the lab or field
Analog output: 0 - 5 V
Digital logging: RS-232 to USB
Data logging: Up to 8,188 records (2,706 incl, Temp/RH)
PC data logging: Software and data cable supplied. Link data to a specific location and monitor.
Clock function: Real time
Power supply: 12V DC ( power adaptor/charge supplied 100-250 V AC)
Rechargeable battery: Lithium polymer 12 V DC 2700 mA/h
Enclosure material and rating: PC and ABS: IP20 and NEMA 1 equivalent
Size: (LxWxD) 195 x 122 x 54 (mm); 7⅝ x 4¾ x 2⅛ (in) (with sensor head)
Weight: < 460 g; < 16 oz (with sensor head and battery)
Environmental operation conditions: Temperature: -5°C to 45°C| Humidity: 0 to 95 % non-condensing
Temperature & Humidity sensor: Range -40°C to 124°C ( -40°F to 255°F); Range: 0 to 100% RH
Approvals: Part 15 of FCC Rules; EN 50082-1: 1997: EN 50081-1: 1992