Input: Single Phase 220V±22V,50Hz±5Hz
Voltage: 0-330V
Current: 0-30A
Power: 0-9kVA
Display: LCD,4 digits
Ripple&Noise 20Hz-20MHz
+ Vrms: 300mV
+ Vpp: 900mV
Noise: ≤65db(A)
Over Load: 105% 200%
Protection Function: Input lack phase protection(three phase); Output over current/over voltage protection; inverted and short circuit protection; Over heat protection
Transient Response Time: ≤10ms
Max. Lead Wire Voltage Drop Compensation: 15V
Communication Function: RS232(standard)/RS485(Optional)
Dimension W×H×D(mm): 441×177.8×550
Weight: 50 kg
Product Detail
Main features:
Work mode: CV, CC
Use high frequency PWM and full-bridge convert technique to achieve high effect
High power density design, standard case, wide application.
LCD display, make operation simple and easily
9 setting and quick recall groups
Perfect output stability. Source voltage effect<0.04 %, Load effect<0.03%, Temperature drifts <0.03 %, time varying drifts <0.25 %
Output line voltage drop compensation, ensure the voltage accuracy under big current
Providing RS232 (standard), (optional), suitable for remote control.
Protect function: output short, output over current, output limit current, over heat protection.
Order Data:
AN504XX 35V output, 1.5kW/3kW/6kW/9kW/15kW/30kW
AN505XX 60V/80V output, 1.5kW/3kW/6kW/9kW/15kW/30kW
AN506XX 120V/150V output, 1.5kW/3kW/6kW/9kW/15kW/30kW
AN507XX 330V output, 1.5kW/3kW/6kW/9kW/15kW/30kW
AN508XX 630V output, 15kW/30kW
0-330V DC Power Supply
<td style="border-top:none;border-left:none;border-bottom:solid #3366FF 1.0pt; border-ri
|
Model
|
AN50700S(F)
|
AN50701S(F)
|
AN50702S(F)
|
AN50703S(F)
|
AN50705(F)
|
AN50710(F)
|
|
Input
|
Single Phase 220V±22V,50Hz±5Hz
|
3-phase,3-line 380V±40V,50Hz±5Hz
|
|
Output
|
Voltage
|
0-330V
|
|
Current
|
0-5A
|
0-10A
|
0-20A
|
0-30A
|
0-50A
|
0-100A
|
|
Power
|
0-1.5kVA
|
0-3kVA
|
0-6kVA
|
0-9kVA
|
0-15kVA
|
0-30kVA
|
|
Display
|
|
LCD,4 digits
|
|
Setting Accuracy
|
Voltage
|
(100V-330V):≤±1%*reading (3V-100V):≤±1%*reading±1V
|
|
Current
|
≤±1% (reading+measurement)
|
|
Read Back Accuracy
|
Voltage
|
(100V-330V):≤±1%*reading (3V-100V):≤±1%*reading±1V
|
|
Current
|
≤±1% (reading+measurement)
|
|
Ripple&Noise 20Hz-20MHz
|
Vrms
|
240mV
|
300mV
|
350mV
|
|
Vpp
|
500mV
|
900mV
|
900mV
|
|
Power Voltage Effect
|
±0.2%
|
|
Load Effect
|
±0.2%
|
|
Noise
|
≤55db(A)
|
≤65db(A)
|
≤70db(A)
|
|
Effciency
|
≥ 0.85
|
|
Over Load
|
100% 110%<="" span="">
|
105% 200%<="" span="">
|
|
Protection Function
|
Input lack phase protection(three phase); Output over current/over voltage protection; inverted and short circuit protection; Over heat protection
|
|
Transient Response Time
|
≤10ms
|
|
Max. Lead Wire Voltage Drop Compensation
|
15V
|
|
Communication Function
|
RS232(standard)/RS485(Optional)
|
|
Memory Function
|
Can preset 10 groups parameters
|
|
Measurement Function
|
5 setting groups and 10 steps sequence,3 working mode for every step, max cycle3000 times
|
|
Temperature Drifts
|
0.04%Vmax/℃
|
|
Time Drifts
|
0.3%Vmax
|
|
Working Conditions
|
Operating Temperature:0℃-40℃;Operating Humidity:10-95%
|
|
Dimension W×H×D(mm)
|
441×88.9×630 (19 inch standard case, 2U height)
|
441×177.8×550
|
550×1200×660
|
|
Weight
|
20kg
|
50kg
|