For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Ainuo AN9638H(F) Multiple function Electrical Safety analyzer (5000V/100mA, Ground test 64A)

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

1) AC Hipot test
Rated output capacity: 5000V/100mA,short circuit current >200mA
Voltage range,Accuracy : 0.01~5.00kV,±1.5%
Frequency range,Accuracy: 50Hz or 60Hz,±0.1%
Current range,Accuracy: 0.10~100.00mA,±2%
2) DC Hipot test
Output voltage setting: 100~6000VDC,±2%
Voltage range,Accuracy: 0.01~6.00VDC,±1.5%
Frequency range,Accuracy: 0.0~10000uA,±2%
Current range,Accuracy: 0.1~999.9s,±0.2%
3) Insulation Resistance test
Output voltage setting: 100~2500Vdc,±2%
Resistance range, accuracy:
+ 1~9999MΩ; 100-499V,1~1000MΩ,±8%
+ 1000~2000MΩ,±12%
+ 500-2500V,1~199MΩ,±2%
+ 200~999MΩ, ± 5%
+ 1000~9999MΩ, ± 15%
4) Ground Bond test
Rated output: Max output current is 64A,max testing resistance 600mΩ,open-circuit voltage <12v br=""> Current range,accuracy: 2.0~32.0A(hoặc 64A),±2%
Voltage range,accuracy: 3.0~10.0V ,±2%
Resistance range, accuracy: 10.0~99.9~100~600mΩ;±2%
Dimension: 426x133x550mm
Weight: 30 kg

 

Product Detail

Main features
* Latest international standard:Comply with CCC,IEC,EN,VDE,BS,UL,JIS standard requirements,500VA WITHSTAND(AC 5KV/100mA),short-circuitoutput current exceeds 200mA,Ground resistance test current up to 64A,optional resistance or voltage mode.7 kinds of built-innetworking MD card for leakage contace current test,complying with multiple industrial standards.
★ Latest international standard: Comply with CCC, IEC, EN,VDE, BS, UL,JIS standard requirements. 500VA withstand (AC 5kV/100mA), short-circuit output current exceeds 200mA. Ground resistance test current up to 64A, optional resistance or voltage mode. 7 kinds of built-in networking MD card for leakage contact current test, complying with multiple industrial standards.
★ Intelligent test: 15 groups of test memories (group name editable), 8-step programming for each group. Product bar code reading and identification, automatically call the test group according to the model/specifications of the products tested. With U-disk to save test data timely.
★ Auto control: RS232/RS484/GPIB (four), bar code scanner interface, PLC interface, easily forming automation system.
★ Information management: optional electrical safety monitoring and control system software (ESRS), realizing test process and data management, high test efficiency, convenient for analysis and tracing.

★ Simplified operation: LCD display, shortcuts, Chinese/English.

Order information:

■AN9638H, 500VA(5000V/100mA) AC/DC withstand voltage, ground test (64A).

■AN9637H, 200VA(5000V/40mA) AC/DC withstand voltage, ground test (32A).

Spec

AC Hipot test

Rated output capacity

AN9638H(F)

500VA(5000V/100mA),short circuit current >200mA

AN9637H(F)

200VA(5000V/40mA),short circuit current >200mA

Output voltage setting

Range,Accuracy

100~5000V,±(2%×setting+5counts)

Output frequency setting

Range,Accuracy

50Hz or 60Hz,±0.1%×setting

Alarm current limits setting

Upper-limit range,Accuracy

0.10~100.00mA(or 40.00mA),±(2%×setting+5counts)

Lower-limit range,Accuracy

0.000~9.999mA,±(2%×setting+5counts)

Time setting

Range

0.5~999.9s(0 is infinite)

Ramp up/down time range

0.1~999.9s

Accuracy

±(0.2%×setting+1count)

Measurement

Voltage range,Accuracy

0.01~5.00kV,±(1.5%×reading+1count)

Frequency range,Accuracy

50Hz or 60Hz,±0.1%×reading

Current range,Accuracy

0.10~100.00mA(or 40.00mA),±(2%×reading+2counts)

Time range,Accuracy

0.1~999.9s,±(0.2%×reading+1count)

Output voltage waveform, distortion, regulation

Sine wave,<2%(pure resistance load),<2%×setting+5V)(from empty load to full load)

Start voltage setting

(0%~50%)×output voltage setting

Current compensation setting

0.000~100.00mA(or 40.00mA),auto、manual

Arc detection

1~9 level,9 level is optimally sensitive,0 is OFF

DC Hipot test

Output voltage setting

Range,Accuracy

100~6000VDC,±(2%×setting+5counts)

Alarm current limits setting

Upper-limit,Accuracy

0~10000μA,±(2%×setting+5counts)

lower-limit,Accuracy

0.0~999.9μA,±(2%×setting+5counts)

Time setting

Range

0.5~999.9s(0 is infinite)

Ramp up time range

0.1~999.9s

Ramp down time range

0.3~999.9s(0 is OFF)

Accuracy

±(0.2%×setting+1 count)

Measurement

Voltage range,Accuracy

0.01~6.00VDC,±(1.5%×reading+1count)

Frequency range,Accuracy

0.0~10000uA,±(2%×reading+5count)

Current range,Accuracy

0.1~999.9s,±(<span style="font-size:9.0pt; font-family:"Times New Roman

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts