ACW
+ Out voltage range: 500~3000VAC,10V/step, ±(2.5%×setting+10V)
+ Output frequency: 50/60Hz, ±0.1%×Setting
+ Breakdown current range: 0.100~20.00 mA, ±(2.5%×reading+5 counts)
IR
+ Output voltage range: 500~3000VAC,100V/step; ±5%×setting
+ Energy capatitor:Standard 0.255uH
+ Sampling frequency:50kHz~40MHz,15 adjustemnt range
+ Test time:1~10 times continuous
IW
+ Pulse voltage range: 500~3000VAC,100V/step; ±5%×setting
+ Energy capatitor:Standard 0.022uH
+ Sampling frequency: 50kHz~40MHz,15 adjustment range
Weight: 33 kg
Main features
* Wingding reverse:Check if the stators winding is reversed
* Multi-Channel:Provide 8 channels configuration to 2 station mode,16 channels configuration to single station mode
* Large ACW capacity:Standard is 3KV/20mA,but can be up to 5KV/100mA
* Large IW capacity:IW is improved to 0.1uF storage capatitor,strongger identification
* Modify ACW mode:Case Hight voltage,wire high voltage and phase to phase mode.
Application
Suitable to test the stator of Y/△ type 3 phase motor,Single phase motor,Brushless motor,Car alternator motor, Synchronous motr,Multi-speed motro.

Accessories
* Connection fixture
Clamp,terminals,probe(elastic and unelastic type)
*Start control mode
Button on test bench,protection cover,barcode,remote box,foot pedel
* Return terminal accessories V groove,circle bridge,metal board,self-priming return teminals

|
Model |
AN96951(F) |
AN96950(F) |
AN9653(F) |
|
ACW |
Out voltage range:500~3000VAC,10V/step.(5000V can be modified) Voltage accuracy:±(2.5%×setting+10V) Output frequency:50/60Hz Frequency accuracy:±0.1%×setting Breakdown current range:0.100~20.00 mA(100Ma can be modified) Current accuracy:±(2.5%×reading+5 counts) |
||
|
IR |
Output voltage range:500~3000VAC,100V/step.(5000V can be modified) Voltage peak accuracy:±5%×setting Energy capatitor:Standard 0.255uH,0.047uH is optinal Front time of impulse:0.5uS Sampling frequency:50kHz~40MHz,15 adjustemnt range Test time:1~10 times continuous Ajustment:Area,differ |
||
|
IW |
Pulse voltage range:500~3000VAC,100V/step.(5000V can be modified) Voltage peak accuracy:±5%×setting Energy capatitor:Standard 0.022uH,0.047uH is optinal Front time of impulse:0.5us Sampling frequency:50kHz~40MHz,15 adjustment range Test time:1~10 times continuous Ajustemnts:Area,differ |
||
|
DCR |
---- |
Range:0.020~0.200~2.000~20.00~200.0~2000~20000Ω Accuracy:±(0.3%×reading + 3 counts) |
--- |
|
Power/Voltage start |
--- |
Voltage range: 20~300V,10V/step. Accuracy:±(0.3%×reading +0.2%×range) Current range: 0.20~2.00~20.00A Accuracy:±(0.3%×reading + 0.2%×range) Active pwer range: 1.0~99.9W~6KW Accuracy:±(0.8%×reading +0.2%×range) Frequency range:45~500Hz Accuracy:± 0.1% ×reading |
Voltage range: 20~460V,10V/step. Accuracy:±(0.3%×reading +0.2% ×range) Current range: 0.05~6.00~40.00A (100Ma can be modified) Accuracy:±(0.3%×reading + 0.2% range) Active pwer range: 1.0~99.9W~18kW Accuracy:±(0.8%×reading +0.2×range) Frequency range:45~65Hz Accuracy:±0.1%×reading |
|
C voltage |
--- |
Voltage range:60.0~600.0V Accuracy:±0.6%×reading |
--- |
|
Speed |
--- |
Range:120~99,999rpm Accuracy:±0.1%×reading+1 |
--- |
|
Rotation |
--- |
RW/RS/RI/KEEP |
--- |
|
PG single |
--- |
PG power:5V or 12V Voltage test:0.50~15.0V Accuracy:±(0.5×reading +2 counts) Frequece range:10~1000Hz Accuracy:±0.1%×reading+1 count |
--- |
|
Weight(without packaging) |
33Kg |
||