Input: 3-phase 4-wires,AC: 380V±57V,50/60Hz±3Hz
Output Capacity: 45kVA
Output Frequency: 45.0~240.00Hz
Frequency Stability: ≤0.02%
Output Mode: 3 phaes mode, Seperated 3 phaes mode,parallel mode
Output Current: 68.2A
Line Regulation: ≤1%
Load Regulation: ≤1%
Phase retardation: 120°+2°
Modulating voltage range: ≤3V
Protection Mode: IGBT hot, IGBT OverCurrent, Transformer hot, Input Lack Voltage, Input Over Voltage, Output Lack Voltage, Output Over Voltage, Output Over Current, Output Over Power, Lack Output Phase
Voltage Drop Compensation: 0.000~0.500Ω
Communication:RS232(Standard), RS485(Options), GPIB(Options),Ethernet(Options)
Remote Control:Analog Control(Options)
Dimension W×H×D(mm): 700*1330*1218
Weihgt (kg): 470
Product Detail
Main features
* Adopt FPGA digital technology,realize precision control and high quality sine wave output;
* Advanced power output mode management:standard three-phase output,separated three-phase output(three-phase voltage and frequency adjusted independently), parallel single-phase output(three phase parallel,single-phase output)to achieve multi-function;
* Operating in over current shock(up to 3 times of rated current) within 2s,start the impact load of 1/3 capacity of powersupply directly;
* Adjustable voltage and frequency during output status,frequency change without transit time;
* Online monitoring:monitor IGBT temperature,transformer temperature,fan speed,input voltage and other parameters during output status;
* Operating data recorders:keep the record of power supply status and alarm code automatically during alarming,save the maintencance time;
* Fan speed will be adjustable automatically with the temperature of power supply to reduce the noise;
* Lock key,user-friendly design,automatically locking without operation for 5 minutes to prevent from opreation mistakes,
* 8 inch color LCD screen;
* Standard RS232,optional RS485,GPIB,Ethernet,analog control and other remote communication/control.
Order and Extensions
* ANFC three-phase AC pwer supply:1.0-300.0v/45.0-65.0HZ,100HZ,120HZ,200HZ,240HZ,optional 15kva,30kva,45kva,60kva,90kva,120kva,180kva,240kva.larger capacity can be modified.
* Communication interfaces:Standard RS-232, optional RS485,GPIB,Ethernet(Remarks:only can select one of RS-232,RS-485,GPIB,Ethernet).
* Remote control interface:optional analog control interface.
* PC control software
Spec.
|
Model/Specification
|
ANFS015A(F)
|
ANFS030A(F)
|
ANFS045A(F)
|
ANFS060A(F)
|
ANFS090A(F)
|
ANFS120A(F)
|
ANFS180A(F)
|
ANFS240A(F)
|
|
Input
|
3-phase 4-wires,AC: 380V±57V,50/60Hz±3Hz
|
|
Output Capacity
|
15kVA
|
30kVA
|
45kVA
|
60 kVA
|
90 kVA
|
120 kVA
|
180kVA
|
240KVA
|
|
Output Frequency
|
45.0~240.00Hz
|
|
Frequency Stability
|
≤0.02%
|
|
Output Mode
|
3 phaes mode, Seperated 3 phaes mode,parallel mode
|
|
Output Current
|
110V
|
45.4A
|
90.9A
|
136.3A
|
181.8A
|
272.7A
|
363.6A
|
545.4A
|
727.2A
|
|
220V
|
22.7A
|
45.4A
|
68.2A
|
90.9A
|
136.3A
|
181.8A
|
272.7A
|
363.6A
|
|
Accuracy
|
Voltage
|
Resolution:0.1V
Accuracy:0.2%×reading+0.2%×F.S. (45Hz—65Hz)
|
|
Current
|
Resolution:0.1A/1A
Accuracy:0.3%×reading+0.3%×rated output
|
|
Frequency
|
Resolution:0.1Hz Accuracy:0.05%
|
|
Power
|
Resolution: 0.1kW / 0.01kW / 0.001kW
Accuracy: 0.45%×reading+0.45%×F.S. (45Hz—65Hz)
|
|
Line Regulation
|
≤1%
|
|
Load Regulation
|
≤1%
|
|
Voltage Distortion
|
Linear load: THD<1.5%(110V±10%,220V±10%,45-65Hz);
|
|
Transient time
|
20ms
|
|
Phase retardation
|
120°+2°
|
|
Phase unbalance factor
|
≤1%
|
|
Crest factor
|
1.41±0.1
|
|
Modulating voltage range
|
≤3V
|
|
Over Power
|
105%≤Output<110% the output will be stopped within 15 Sec.
110%≤Output<210% the output will be stopped within 5 Sec.
200%≤Output<300% the output will be stopped within 2 Sec.
300%≤Output the output will be stopped immediately
|
|
Protection Mode
|
IGBT hot、IGBT OverCurrent、Transformer hot、Input Lack Voltage、Input Over Voltage、Output Lack Voltage、Output Over Voltage、Output Over Current、Output Over Power、Lack Output Phase
|
|
Voltage Drop Compensation
|
0.000~0.500Ω
|
|
Softstart Time
|
0.0~99.9S
|
|
Efficiency
|
>86%
|
|
Shortcut Group
|
7 groups
|
|
Online Voltage Adjustment
|
The output voltage and frequency(45-65Hz) can be adjusted online under running status.
|
|
Communication/
Remote Control
|
Communication:RS232(Standard)、RS485(Options)、GPIB(Options)、Ethernet(Options)</s
|