Measurement Category: CAT III 600 V
Operating voltage: 0 to 600 V AC/DC
Operating frequency: Energized: 6.25 kHz
De-Energized: 32.768 kHz
Hazardous voltage detection: See NCV detection
Signal indications: Numeric, bar graph display and audible beep
Response time: Tip Sensor (energized/de-energized): 500 MS
NCV: 500 MS
Battery voltage monitoring: 5 sec
Current output of signal (typical): N/A
Signal voltage output (nominal): N/A
Range detection (open air):
Tip sensor (Energized):
Max distance via air: up to 20 ft (6.1 m)
Pinpointing: approx. 1.97 in (5 cm)
Tip sensor (De-energized):
Max distance via air: up to 14.7 ft (4.5 m)
Pinpointing: approx. 1.97 in (5 cm)
NCV detection (40 to 400 Hz):
Max. sensitivity: 90 V up to 6.56 ft (2 m)
Min. sensitivity: 600 V up to 0.39 in (1 cm)