Input voltage range: 90 - 264 Vac (wide range); 90 - 264 1200 W load, nominal 100 Vac; 180 - 264 2000 W load, nominal 200 Vac
Frequency: 47 - 63 Hz, single phase AC
Main DC voltage: +12 V @ 164.2 A: 180 - 264 Vac / +12 V @ 100 A: 90 - 264 Vac
Standby: +3.3 Vsb @ 9 A or 5 V @ 6 A
Regulation: +12 Vdc; ±5% / +3.3 Vsb/+5.0V; ±5%
Operating temperature: -10 °C to 50 °C
Storage temperature: -40 °C to +85 °C Altitude, operating 10,000 ft
Humidity: 20 to 90% RH, non-condensing
Nominal Output Voltage Set Point: 12.2 Vdc; 3.3 Vsb
Set Point Tolerance: ±0.2%; ±1%
Minimum Current: 0 A; 0A
Maximum Current: 161.5 A ; 9.0 A
Output Ripple P/P: 120 mV; 60 mV
Overcurrent: 120 - 130% of nominal; 100 - 125% of nominal
Airflow: Standard