Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Input voltage range: 180 to 264 Vac: 2000 W; 90 to 140 Vac: 1000 W
Frequency: 47 Hz to 63 Hz
Max input current: 11.5 Arms at 100/200 Vac
Main DC Output
Nominal setting: MIN: 12.175 /NOM: 12.2/ MAX: 12.225
Total output regulation range: MIN: 11.4 V/ MAX: 12.9 V
Output current: MIN: 5.0 A1, 2 (minimum starting load for 17% transient step)/ MAX: 163.9 A at high line; 82 A at low line
Standby DC Output
Nominal setting: MIN: 11.95/ NOM: 12/ MAX: 12.05
Total output regulation range: MIN: 11.4 V/ MAX: 12.6 V
Output current: MIN: 0.0 A/ MAX: 3.5 A
Operating temperature: 0 to 50 °C, allowable up to 60 °C at derated output of 2.6%/°C above 50 °C
Operating relative humidity: Up to 95% non-condensing
Nominal Main Output: 12.2 V @ 163.9 A
Standby Output: 12 V @ 3.5 A
Airflow Direction: Standard (forward)