Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Input
Input range:
85 - 264 Vac (Operating)
115/230 Vac (Nominal) Input through standard IEC connector/ TERMINAL BLOCK
Frequency: 47 - 440 Hz, Nominal 50/60
Input current: 8 A RMS max input current, at 100 Vac
Output
Output rating: See ordering information table: 85 - 264 Vac
Rated load: 600 W maximum. Derate linear to 50% from 50 °C to 70 °C
Minimum load: Main output @ 0.0 A; 5 Vsb @ 0.0 A. No loss of regulation
Operating temperature: -40 °C to +70 °C, linear derating to 50% from 50 °C to 70 °C
Storage temperature: -40 °C to +85 °C
Humidity: 10 to 90%, non-condensing. Operating. Conformal coat option available.
Functions: Short circuit protection; Overload protection (OCP); Overvoltage protection (OVP)
Ordering Information
Output: 24 V
Nominal Output Voltage Set Point: 24 V
Set Point Tolerance: ±0.5%
Adjustment Range: 19.2 - 28.8 V
Current
Min: 0 A
Max: 27 A
Output Ripple P/P (0-50°C): 240 mV
Max Continuous Power: 600 W
Combined Line/ Load Regulation: 2%