Input
Input range: 85-264 Vac; 120-300 Vdc
Frequency: 47-67 Hz
Inrush current: 38 A max, cold start @ 25°C
Output
Maximum powerL:
110 W convection (75 W with cover)
85 W convection - LPQ173
175 W with 30 CFM forced air
(130 W with cover - LPQ172)
Adjustment range:
3.3 - 5.5V on main; -12 - 15V on 3rd output
3.3 - 25 V on 4th output - LPQ172
3.3 - 5.5 V on 4th output - LPQ173
Hold-up time: 20 ms @175 W load at nominal line
Environmental Specifications
Operating temperature: 0 °C to 50 °C ambient. Derate each output 2.5% per degree from 50 °C to 70 °C (except for -C version).
Storage temperature: -40 °C to +85 °C
Humidity: Operating; non-condensing 5% to 95%
Functions: Built-in EMI filter; Overvoltage protection; Overload protection; Thermal overload protection
Ordering Information
Output: Quad
1.
Output Voltage: 5 V (3.3 - 5.5 V)
Minimum Load: 0 A
Maximum Load with Convection Cooling: 10 A
Maximum Load with 30CFM Forced Air: 24 A
Peak Load: 26 A
Regulation: ±2%
Ripple P/P(PARD): 50 mV
2.
Output Voltage: 12 V
Minimum Load: 0 A
Maximum Load with Convection Cooling: 6 A
Maximum Load with 30CFM Forced Air: 8 A
Peak Load: 10 A
Regulation: ±3%
Ripple P/P(PARD): 120 mV
3.
Output Voltage: -12 V (-12 -15 V)
Minimum Load: 0 A
Maximum Load with Convection Cooling: 2 A
Maximum Load with 30CFM Forced Air: 3 A
Peak Load: 3.5 A
Regulation: ±3%
Ripple P/P(PARD): <1%
4.
Output Voltage: 5 V (3.3 - 5.5 V)
Minimum Load: 0 A
Maximum Load with Convection Cooling: 10 A
Maximum Load with 30CFM Forced Air: 24 A
Peak Load: 26 A
Regulation: ±2%
Ripple P/P(PARD): 50mV