Input
Input range: 85 - 264 Vac; 120-300 Vdc
Frequency: 47 - 67 Hz
Inrush current: 38 A max, cold start @ 25°C
Output
Maximum power: 110 W convection (75 W with cover); 175 W with 30 CFM forced air (130 W with cover)
Adjustment range: 2:1 wide ratio minimum
Standby outputs: 5 V @ 2 A regulated ±5%
Hold-up time: 20 ms @175 W load at nominal line
Aux output: 12 V @ 1 A -5 %, +10%
Environmental Specifications
Operating temperature: 0° to 50 °C ambient; derate each output at 2.5% per degree from 50° to 70 °C
Low temperature start: -20 °C
Storage temperature: -40° to 85 °C
Humidity: Operating; non-condensing 5% to 95%
Functions: EMI filter; Safety ground leakage current; Overload protection; Overvoltage protection; Remote sense
Ordering Information
Output Voltage: 15 V (12 - 24 V)
Minimum Load: 0 A
Maximum Load with Convection Cooling: 7.3 A
Maximum Load with 30CFM Forced Air: 12 A
Peak Load: 13.2 A
Regulation: ±2%
Ripple P/P(PARD): <1%