Input
Input voltage range: Universal input: 90 - 264 Vac; 120 - 370 Vdc
Input frequency range: 47 - 440 Hz
Input surge current: 120 Vac, cold start: 15 A max.; 230 Vac, cold start: 30 A max.
Input current: 120 Vac: 1.4 A rms; 230 Vac: 0.7 A rms
Output
Total regulation (Line and load)
Main output: ±2.0%
Auxiliary outputs: ±5.0%
Weight: 200 g (7.06 oz)
Functions: Safety ground leakage current; Overvoltage protection, Short circuit protection, Minimum output current
Thermal performance
Operating ambient (see derating curve): 0°C to +70°C
Non-operating: -40°C to +70°C
50°C to 70°C ambient, convection cooled: Derate to 50% load
0°C to 50°C ambient, convection cooled: 40 W
0°C to 50°C ambient, 20 CFM forced air: 50 W
Peak (0°C to +50°C, 60 s): (See Note 2)
Relative humidity: Non-condensing: 5 to 95% RH
Output: Triple
1.
Output Voltage: +3.3 V (IA)
Output Current:
Max: 4 A
Peak: 5 A
Fan: 4.5 A
Ripple: 50 mV
Total Regulation: ±2.0%
2.
Output Voltage: +12 V (IB)
Output Current:
Max: 2 A
Peak: 3 A
Fan: 3 A
Ripple: 120 mV
Total Regulation: ±5.0%
3.
Output Voltage: –12 V (IC)
Output Current:
Max: 0.2 A
Peak: 1 A
Fan: 0.5 A
Ripple: 120 mV
Total Regulation: ±5.0%