Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Surge voltage generator:
Surge voltage ranges: 0 – 8 kV, 0 – 16 kV, 0 – 32 kV
Options SZ 1000/SZ 1600: 0 – 4 kV
Option SZ 2500: 0 – 3 kV
Surge energy:
SSG 1100: 1,100 J
with option SZ 1000: 880 J
with option SZ 1600: 1,480 J
with option SZ 2500: 2,290 J
Option SSG 1500: 1,540 J
with option SZ 1000: 980 J
with option SZ 1600: 1,580 J
with option SZ 2500: 2,350 J
Option SSG 2100: 2,050 J
with option SZ 1000: 1,110 J
with option SZ 1600: 1,710 J
with option SZ 2500: 2,420 J
Surge sequence: 10 or 20 pulses/min, single surge
Option SSG 1500: 20 or 30 pulses/min, single surge
DC voltage: 0 – 32 kV
Max. output current (in DC mode):
560 mA (0 – 8 kV)
Option SSG 1500/SSG 2100: 850 mA (0 – 8 kV)
IRG 4000 time domain reflectometer:
The technical data of the time domain reflectometry and insulation resistance measurement are provided in the data sheet for the IRG 4000 time domain reflectometer and BAUR Software 4 for cable fault location.
System:
Power supply: 220 – 230 V, 50/60 Hz
Options:
110 – 120 V, 50/60 Hz (with external auto transformer)
240 V, 50/60 Hz (with conversion kit for mains supply)
Ambient temperature (operational): 0°C to +50°C
Extended temperature range: -20°C to +60°C Limitation of performance data possible
Storage temperature: -40 to +60°C
Dimensions (W x H x D): Approx. 935 x 1,145 mm x 775 mm (incl. KTG M3 cable drum rack)
Weight: From 195 kg (depending upon equipment)
Degree of protection: IP22
Safety and EMC: CE-compliant in accordance with Low Voltage Directive (2014/35/EU), EMC Directive (2014/30/EU), EN 60068-2-ff Environmental testing
Standard delivery
BAUR Syscompact 4000 cable fault location system:
▪ IRG 4000 time domain reflectometer incl. pre-installed BAUR Software 4
(cable fault location)
▪ Uninterruptible power supply (UPS)
▪ PC keyboard
▪ Measuring cable (3 m)
▪ SA 32 SIM/MIM coupling unit
▪ SSG 1100 surge voltage generator
▪ SK 1D inductive coupler for ICM
▪ 19” rack, height 27 RU (1,200.15 mm), depth 700 mm
▪ KTG M3 cable drum rack with HV connection cable, mains supply cord
and earth cable (incl. earth terminal), each 25 m
▪ Contact monitoring of the earth terminal
▪ Jumper plug for external emergency off unit
▪ CS 2 HV coaxial connection sockets, 40 kV
▪ GR 40 earth rod
▪ User manual