Output:
Variable Output Voltage: 1 – 16 V
Variable Output Current: 0 – 60 A
Auxiliary Output Current: 5 A
Voltage Regulation:
Load (0-100% Load): ≤ 50 mV
Line (90-132 VAC, 170-264 VAC Variation): ≤ 20 mV
Current Regulation:
Load (10-90% Rated Voltage): ≤ 200
Line (90-132 VAC, 170-264 VAC Variation): ≤ 50 mA
Ripple & Noise:
Ripple & Noise Voltage (rms): ≤ 5 mV
Ripple & Noise Voltage (peak-peak): ≤ 50 mV
Current Ripple & Noise (rms): ≤ 100 mA
Meter Type & Accuracy:
Voltage Meter: 3-Digit LED Display ± 0.2% + 3 counts
Current Meter: 3-Digit LED Display ± 0.2% + 3 counts
Other:
AC Input: 220 - 240 VAC 50 Hz
Full Load Input Current: 4.7 A (230 VAC)
Efficiency: 85% (230 VAC)
Switching Frequency: 65 – 85 kHz
Tracking Overvoltage Protections: O/P 1-5 V: set voltage +2 V; O/P 5-16 V: set voltage +3 V
Transient Response Time: (50-100% Load) 1.5 ms
Power Factor Correction: > 0.95 at optimal load
Cooling Method: Thermostatically controlled fan from zero to full speed
Protections: Overload, Short Circuit by Constant Current, Overvoltage, Overtemperature
Special Features: 3 User-Defined Voltage and Current Presets, Analog Remote Control, Remote Sense (model 1900 only)
Operating Temperature: 32 ~104 °F (0~40 °C), ≤ 80% R.H.
Storage Temperature: 5~158 ºF (-15~ 70 ºC), ≤ 85% R.H.
Dimensions: (W x H x D) 7.9” x 3.5” x 10.8” (200 x 90 x 275 mm)
Weight: 7 lbs (3.2 kg)
Included Accessories: Power cord, instruction manual, remote control connector