Basic measurements:
Voltage, Current: Peak to peak, Maximum, Minimum, Average_rms, Average_rectified, DC,
Crest factor (current), Inrush (current)
Power: Real, Apparent, Reactive, DC, Power factor
Time: Frequency, Phase
Integration: Total power, Total current, Maximum power, Minimum power
Harmonic measurements:
Type: Current, Voltage, Real power, Apparent power, Reactive power, Power factor, Phase, Percentage of total (Current, Voltage, Power)
Range: DC up to 50th order
Max. Frequency: 100 kHz
Input bandwidth: DC, 0.5 Hz to 100 kHz
Measurement method: Digital sampling
A/D Converter: Simultaneous conversion of voltage and current inputs, Resolution: 18-bit, Maximum conversion rate: 10 μs
Line filter: Select OFF or ON (cutoff frequency at 500 Hz)
Peak (max,min): Voltage, current, or power
Input voltage continuous: max. 1.5 kV-peak or 1 kV-RMS, whichever is less
Input voltage transient (<1s): max. 2 kV-peak or 1.5 kV-RMS, whichever is less
Input voltage common-mode: max. 600 Vrms
Voltage input impedance: 2 MΩ + 13 pF in parallel (typical)
Current input impedance (typical):
5 mA to 200 mA range: 505 mΩ + 0.1 μH
0.5 A to 20 A range: 5 mΩ + 0.1 μH
Sensor input: 20 kΩ (50 mV to 2 V)/100 kΩ (2.5 V to 10 V)
Input current continuous max.:
5 mA to 200 mA range: 30 A-peak or 20 A-RMS, whichever is less
0.5 A to 20 A range: 100 A-peak or 30 A-RMS, whichever is less
Sensor input: Peak value less than or equal to 5 times the rated range
Input current transient (<1s) max.:
5 mA to 200 mA range: 30 A-peak or 20 A-RMS, whichever is less
0.5 A to 20 A range: 150 A-peak or 40 A-RMS, whichever is less
Sensor input: Peak value less than or equal to 10 times the rated range
Voltage measurement ranges:
CF=3: 15 V, 30 V, 60 V, 150 V, 300 V, 600 V
CF=6: 7.5 V, 15 V, 30 V, 75 V, 150 V, 300 V
Display: 4.3” TFT-LCD display, 480 x 272
Remote Interfaces: USB (USBTMC-Compliant), RS232, LAN
Power: 100 to 240 VAC, 50 / 60 Hz
Power Consumption: 50 VA max.
Dimensions (W x H x D): 8.4” x 3.5” x 14” (214.5 mm × 88.2 mm × 354.6 mm)
Weight: 6.2 lbs (2.8 kg)
Standard Accessories: Getting started manual, instruction manual (downloadable), AC power cord, USB type: A-to-type B cable, certificate of calibration