Measurement Parameters: L/C/R/Z/D/Q/θ/ESR
Test Frequency Setting: 100 Hz,120 Hz, 1 kHz, 10 kHz
Actual Frequency (±0.02%): 100 Hz, 120.048 Hz, 1 kHz, 10 kHz
Test Signal Level (Typical): 0.6 Vrms
Measuring Circuit Mode: Series mode / Parallel mode
Basic Accuracy: 0.5%
Ranging Mode : Auto
Response Time (Typical): 680 ms
Auto Power-Off: 5, 15, 30, 60 minutes, none
Operating Temperature: 32° F to 104° F (0° to 40° C); 0-70% R.H
Storage Temperature: -4° F to 122 °F (-20° to +50° C); 0-80% R.H.
Low Battery Indication (Typical): 6.8 V
Battery Life (Typical): 16 hours using alkaline battery (at 1 kHz with 100 Ω DUT, backlight off), 6 hours using Ni-MH (880 only)
Power Consumption (Typical): 28 mA (under full power battery) for operation/ 2 µA (11 µA 880 only) after power-off.
Power Requirements: 9V battery or Ext. adapter 230V: DC 12 Vmin –15 Vmax. (load 50 mA Min.)
Dimensions (L x W x H): 7.5” x 3.5” x 1.6” (190 × 90 × 41) mm
Weight: 0.767 lbs (348 g) without battery
Safety: EN61010-1:2001, EU Low Voltage Directive 2006/95/EC
Standard Accessories: Banana-to-alligator test leads, Ni-MH 9 V battery, mini USB interface cable, Quick Start insert, AC adapter* shorting plate, four-terminal shielded Kelvin clip test leads (TL8KC1), SMD tweezer (TL8SM)Measurement Parameters: L/C/R/Z/D/Q/θ/ESR
Test Frequency Setting: 100 Hz,120 Hz, 1 kHz, 10 kHz
Actual Frequency (±0.02%): 100 Hz, 120.048 Hz, 1 kHz, 10 kHz
Test Signal Level (Typical): 0.6 Vrms
Measuring Circuit Mode: Series mode / Parallel mode
Basic Accuracy: 0.5%
Ranging Mode : Auto
Response Time (Typical): 680 ms
Auto Power-Off: 5, 15, 30, 60 minutes, none
Operating Temperature: 32° F to 104° F (0° to 40° C); 0-70% R.H
Storage Temperature: -4° F to 122 °F (-20° to +50° C); 0-80% R.H.
Low Battery Indication (Typical): 6.8 V
Battery Life (Typical): 16 hours using alkaline battery (at 1 kHz with 100 Ω DUT, backlight off), 6 hours using Ni-MH (880 only)
Power Consumption (Typical): 28 mA (under full power battery) for operation/ 2 µA (11 µA 880 only) after power-off.
Power Requirements: 9V battery or Ext. adapter 230V: DC 12 Vmin –15 Vmax. (load 50 mA Min.)
Dimensions (L x W x H): 7.5” x 3.5” x 1.6” (190 × 90 × 41) mm
Weight: 0.767 lbs (348 g) without battery
Safety: EN61010-1:2001, EU Low Voltage Directive 2006/95/EC
Standard Accessories: Banana-to-alligator test leads, Ni-MH 9 V battery, mini USB interface cable, Quick Start insert, AC adapter* shorting plate, four-terminal shielded Kelvin clip test leads (TL8KC1), SMD tweezer (TL8SM)