Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Output
Phases: 3 (A,B,C)
Phase Angles: A=0°, B=240°, C=120°
AC Power: 675VA Max per phase
Load Connection Floating neutral (option): Rear panel terminal block
RP Series : Product Specifications
Output : Voltage
High range / Low Range: 0-270/0-135 V RMS (except -AV)
Accuracy: ± 0.1 %FS @ 16Hz-100 Hz
Accuracy: ± 0.2%FS @ 100Hz-5000Hz
Resolution: 0.1 V
Load Regulation remote sense: 16-500Hz, ± 0.1% FS
Line Regulation 10 % Line change: ± 0.02%FS
T.H.D: 16-100Hz 0.5 typ./1.0 max.%; 100-2000Hz 1.0 typ./2.0 max.%
Output Noise: < 0.1 V RMS typ.
Output : Frequency (specifications valid from 45 Hz to 500 Hz)
Range: 16 - 5000Hz
Accuracy: ± 0.02%
Resolution
16.0Hz-80.0Hz 0.01 Hz
80.1Hz-800.0Hz 0.1 Hz
800Hz-5000Hz 1Hz
Output : Current
Steady State Current High V range: 2.5 A rms / ø
Steady State Current Low V range: 5.0 A rms / ø
Peak Current High V range: 7.5 A peak / ø
Peak Current Low V range: 15.0 A peak / ø
Input
Line Voltage 2 wire + GND: 107/115V or 208/230V ± 10% V RMS (set by jumper)
Line Current (fused): <30@115V,<15@230V A RMS
Line Frequency: 47 - 440 Hz
Holdup Time: 10 ms
Power Factor: 0.7
Isolation Input/output to Chassis: 1350 V / 2200 V
Please check the datasheet for details