Insulation
Terminal Voltage: Range - Max Resolution - Accuracy - Test Current - Short circuit current
125V (0% ~ + 10): 0.125~4000MΩ ; 0.001MΩ ; ±(2% + 10) ; 1mA at load 125kΩ ; ≤1mA
250V (0% ~ + 10): 0.250~4000MΩ ; 0.001MΩ ; ±(2% + 10) ; 1mA at load 250kΩ ; ≤1mA
500V (0% ~ + 10): 0.500~4000MΩ ; 0.001MΩ ; ±(2% + 10) ; 1mA at load 500kΩ ; ≤1mA
1000V (0% ~ + 10): 1.000~4000MΩ ; 0.001MΩ ; ±(3% + 10) ; 1mA at load 1MΩ ; ≤1mA
Low OHM
Range - Resolution - Accuracy - Max. open Circuit Voltage - Overload Protection
4.000Ω ; 0.001Ω ; ±(1.5% + 30) ; 5.8V ; 250Vrms
40.00Ω ; 0.01Ω ; ±(1.5% + 3) ; 5.8V ; 250Vrms
400.0Ω ; 0.1Ω ; ±(1.5% + 3) ; 5.8V ; 250Vrms
Continuity Beeper
Range: Resolution - Operation Resistance - Max. open Circuit Voltage - Overload Protection
Continuity: 0.01Ω ; Resistance≤35Ω ; 5.0V±1VDC ; 250Vrms
Short circuit current: ≥200mA
LOOP Resistance
L-PE (Hi-Amp)
Range (Ω) - Max. Resolution (Ω) - Accuracy
0.00~999 ; 0.01 ; ±(4% of reading + 6 digits)
L-PE(No Trip): Measuring Current:15mA / Range of the Voltage Used: 195V a.c.~260V a.c.(56,60Hz)
Range (Ω) - Resolution (Ω) - Accuracy
0.00~999 ; 0.01 ; ±(5% of reading + 6 digits)
L-N: Measuring Current:2.0A / Range of the Voltage Used:195V a.c.~260V a.c.(56,60Hz)
Range (Ω) - Max. Resolution (Ω) - Accuracy
0.00~999 ; 0.01 ; ±(4% of reading + 4 digits)
RCD Testing
Test current - Accuracy
x1/2, x1, x2, x5 ; 1.5%~ -9%
Voltage and Frequency
Measurement Range (V)/ AC/DC - Resolution - Accuracy
80-500V/(45-400Hz) ; 1V ; ±(2% of reading + 2 digits)
Size (H x W x D): 220mm x 96.5mm x 60.5mm
Weight: 631g
Accessories: Test leads, 8 x1.5V“AAA” batteries, USB cable and Software, gift box with carrying case.
Datasheet
Features |
3.5" TFT color LCD display with 320x240 pixels |
Fast high current loop test |
Variable RCD current mode for customized settings |
PASS/FAIL indication for RCD tests |
Select voltage measurement between L-N, L-PE and N-PE |
Support SD memory and USB and Bluetooth interface |
Internal Memory |
Safe Earth Volt Touchpad detects raised earth voltages >50 V, indicating potential dangerous situations. |
Slim probes designed with test button |
For easy, always reliable and accurate compensation of test leads and mains cords. |