- Applicable Standards:
IEC 61672-1:2013 Class 2
IEC 61672-1:2002 Class 2
IEC 60651:2001 Type 2 I
IEC 60804:2000 Type 2
IEC 61252:1993 Personal Sound Exposure Meters
ANSI S1.4 -1983 (R2006), ANSI S1.43 - 1997 (R2007)
ANSI S1.25:1991
- Microphone: Class 2 MK:216 pre-polarized
- Microphone Preamplifier: MV:200 Removable Preamplifier (All versions)
- Total Measurement Range:
20dB to 140dB RMS Single Range
Noise Floor: <21dB(A) Class 2
- Frequency Weightings: RMS & Peak : A, C, & Z Measured Simultaneously
- Time Weightings: Fast, Slow & Impulse Measured Simultaneously
- Display: High resolution display. Ambient light sensor & illuminated keypad
- AuditStore: Measurement verification data stored in secure memory
- Time History Data Rates (Global settings): 10ms, 62.5ms, 125ms, 250ms, 1/2 sec, 1 sec, 2 sec (User selectable)
- Integrators:
Three simultaneous "virtual" noise meters. Integrator 1 is preset to Q3 for Leq functions. Integrators 2 & 3 can be configured with the following:
Exchange Rate: 3, 4 or 5 dB
Threshold: 70dB to 120dB (1 dB steps)
Time Weighting: None or Slow
Criterion Level: 70dB to 120dB (1 dB steps)
Criterion Time: 1 to 12 hours in 1 hour steps
- Integrator Quick settings:
EU, OSHA HC & OSHA NC, OSHA HC & ACGIH,
MSHA HC & MSHA EC, Custom 1 & Custom 2
- Measurement control: Pause & Back Erase with user selectable duration
- Dimensions:
Size: 283mm x 65mm x 30mm
Weight: 300gms/10oz
- Batteries: 4 x AA Alkaline
- Battery life
Typically 12 hours with Alkaline AA
Typically 20 hours with Lithium AA Non-Rechargeable
Battery life is dependent upon the battery type, quality & screen brightness
- Connections:
USB Type B to PC
AC & DC Output via ZL:174 (2 x Phono, 1m)
Multi-pin IO for external power via ZL:171 cable (2.1mm socket)
External Power: 5v-15v via MultiIO socket via ZL:171 cable (2.1mm socket)
- Tripod Mount: 1/4" Whitworth socket
- Case: Material: High Impact ABS-PC with soft touch back & keypad
- Environmental:
Temperature: Operating -10°C to +50°C, Storage -20°C to +60°C
Humidity: Up to 95% RH Non Condensing
Measurement Functions
- Displayed Functions
LXY, LXYMax, LXYMin, LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE
Graph of Short LAeq, LCPeak
Integrators 2 & 3: TWA, Dose%, Est Dose%v
Measurement Run Time