Gas Detected: VOC (Calibration Gas: Toluene)
Sampling Method: Extractive
Detection Principle: Hot-wire semiconductor
Detection Range: Low range: 0 to 100 ppm; High range: 0 to 1000 ppm
Indication Accuracy: ± 10% of full scale
Display: Main LCD: Digital-LCD with backlight; Sub LCD: Clock display
Alarm: Non-alarm
Explosion-proof Structure: Ex ib d IIB T3 (TIIS)
Operation Temperature: 0 to +40 °C
Power Source: 4 x AA alkaline dry battery
Continuous Operation: With alkaline battery: approx 25 hours (at 20°C, backlight OFF)
Dimensions: W82 x H162 x D36 mm
Weight: Approx. 450g (excluding batteries)
Standard Accessories: Soft case, 4 x AA alkaline dry battery, Gas sampling hose (1m, for solvent model SH-401), Replacement filter, Probe with filter/moisture trap
Optional Items: Datalogger kit (CD-ROM + USB cable), AC adaptor, Activated carbon filter set