Air bubbles that form during stirring not only affect mixing efficiency but can also skew analytical results in some laboratory applications. Learn about the causes and effective ways to minimize them

Do air bubbles appear when stirring and affect the results?

Seeing a small layer of bubbles on the surface of a solution, most users usually continue their work without much concern. However, in many laboratory tests, the amount of gas entrained in the sample is a detail that can make a difference between two analytical results.

Some solutions are almost unaffected by the appearance of a small amount of bubbles during stirring. Conversely, there are applications where even a small amount of gas in the sample is enough to alter the measured value or affect the repeatability of the results.

Where do the bubbles come from?

Most air bubbles form when swirling currents on the surface of the solution draw air from the outside into the container. This often occurs when the stirring speed is set higher than necessary or the size of the stirring rod is not suitable for the sample volume.

Some solutions also tend to retain air longer than normal. Samples containing proteins, polymers, surfactants, or viscosity-enhancing additives are more prone to foaming than distilled water or simple solvents.

Temperature also contributes to this phenomenon. When the solution is heated during stirring, the physical properties of the sample change, and the likelihood of foam formation can increase significantly.

When do air bubbles start affecting the results?

If the purpose is simply to dissolve chemicals or prepare a standard solution, a small amount of foam appearing for a short time usually doesn't make a significant difference.

The story changes when the sample is moved to subsequent measurement or analysis steps. Air bubbles present in the solution can alter the actual volume of the sample, affecting homogeneity or creating errors in certain physical measurements.

Determining viscosity, density, electrical conductivity, or other parameters related to dissolved components is often more sensitive to this phenomenon. The more gas present in the sample, the greater the likelihood of discrepancies between tests.

Does more foam mean more effective stirring?

A cup of solution with strong swirling and a lot of foam often gives the impression that the stirring process is going very well. In reality, the amount of foam doesn't directly reflect the effectiveness of mixing.

The goal of stirring is to help distribute the components evenly throughout the solution. When the swirling is too strong, some of the system's energy is used to draw air from the outside into the sample.

As a result, the amount of foam increases, but the mixing efficiency may not improve accordingly. In many cases, reducing the stirring speed to a more appropriate level yields more stable results.

Why do bubbles still appear even after the speed has been reduced?

This phenomenon often leads many people to mistakenly believe that the stirrer is malfunctioning.

In reality, the properties of the solution are the determining factor in many cases. Some samples have the ability to retain air for a very long time, so even when the stirring speed is adjusted appropriately, foam will still remain on the surface or suspended in the solution.

The size of the stirring bar also significantly affects the flow formed inside the beaker. A stirring bar that is too small often creates a deeper vortex to maintain mixing, thereby increasing the likelihood of air being drawn from the surface.

In applications requiring precise stirring control, choosing equipment capable of maintaining a stable speed, such as the DLAB MS-H280-Pro, allows operators to control working conditions more easily, especially when handling samples sensitive to foaming.

Read more related articles: Magnetic stir bar loses magnetism, how to fix it quickly?

How can we reduce air bubbles?

The simplest solution is to reduce the stirring speed to a level sufficient to maintain uniform fluid movement.

If the phenomenon persists, check the size of the stirring rod, the sample volume, and the shape of the container. A suitable combination usually results in a more stable flow and limits the amount of air trapped below.

For tests requiring high accuracy, the sample is often left undisturbed after stirring to allow any remaining air to escape before measurement or analysis.

Air bubbles are sometimes just minor details that appear during sample preparation. However, in many laboratory applications, this small detail is the cause of discrepancies in test results that operators may not immediately notice.

Related News

The scent of new wood in a newly handed-over apartment: How to measure and address formaldehyde (HCHO) levels before moving in
11/14/2026 10:28:19

Many people refer to the pungent, acrid odor that emerges when opening a new cabinet as the "smell of new wood," assuming it will simply dissipate after a few days. In reality, however, what is being released could well be formaldehyde—a substance originating from the adhesives used in the pressed-wood panels—and our sense of smell is not a reliable enough gauge to determine the concentration levels present

Guide to Selecting a TCLP Toxicity Characteristic Leaching Procedure Shaker Configuration in Compliance with QCVN 07:2025/BNNMT and TCVN 9239:2012
11/13/2026 17:23:39

Regulation QCVN 07:2025/BNNMT (replacing QCVN 07:2009/BTNMT and QCVN 50:2013/BTNMT) specifies hazardous waste and sludge thresholds based on leachate concentrations. To ensure that analytical results for heavy metals and organic compounds are accepted during ISO/IEC 17025 or VIMCERTS assessments, laboratories must comply with the Toxicity Characteristic Leaching Procedure (TCLP) specified in TCVN 9239:2012, which is equivalent to US EPA Method 1311

Checking the Temperature of Paint and Coating Surfaces After Curing Using an Infrared Thermometer
11/13/2026 16:11:22

An infrared thermometer allows surface temperature measurement without direct contact, making it suitable for products coming out of curing ovens or surfaces that are difficult to access. However, to ensure reliable results for production quality control, it is important to understand the measurement principle and the factors that affect measurements on painted and coated surfaces.

Crowded Gyms and Yoga Studios: How to Manage Air Quality to Retain Members
11/13/2026 15:07:40

Around 6 or 7 in the evening, the gym becomes packed; the music drowns out the sound of heavy breathing, and the air conditioning runs at full blast behind closed doors. At first glance, everything seems fine: the room is cool, the lights are bright, and the equipment is state-of-the-art. Yet, after just a few sessions, regular members begin to feel a heavy-headedness and find themselves running out of breath more quickly eventually, they simply stop renewing their memberships. No one complains about the personal trainers or the exercise machines. The very thing that makes them feel stifled and drives them away is something entirely invisible: the air inside the room

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts