Doble-Megger DLRO10 Digital Microhmmeter (1.9999 mΩ~1999.9 Ω)
Resistance ranges
Full Scale: 1.9999 mΩ~1999.9 Ω
Resolution: 0.1 μΩ~100 mΩ
Measurement mode: Manual, Auto, Continuous, Inductive
Measurement control: Fully Automatic
Measurement speed: <3s for forward and reverse current and to display average
Display Measurement: 4 1/2 digit seven segment LED
Range and safety: DLRO10 LED indications
Test method: Single cycle reversing DC ratiometric measurement - average result display.
Test current accuracy: ±10%
Test current stability: <10 ppm per second
Lead resistance: Maximum 100 mΩ total for 10 A operation irrespective of battery condition.
Voltmeter input impedance: >200 kΩ
Noise rejection: Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads.
Warning will show if hum or noise exceeds this level.
Battery type: 5.2 lithium ion rechargeable
Battery life: Typical 1300 x 10 A tests before recharge
Battery charge time : Via external 90 V – 260 V 50/60 Hz charger from 12 to 15 V DC supply
Standard: 2.5 hours to 90% capacity, 4 hours to fully charged
Slow Charge: +10 °C to + 45 °C (50 °F to 113 °F)
Operating temperature range and humidity:
+5 °C to +45 °C (41 °F to 113 °F) at full accuracy
-10 °C to +50 °C (14 °F to 122 °F) at reduced accuracy
<90% RH @ 40 °C (104 °F) non-condensing
Storage temperature range and humidity
-30 °C to +70 °C (50 °F to 113 °F)
<90% RH @ 40 °C (104 °F) non-condensing
Temperature co-efficient: <0.01% per °C, over range 5 °C to 40 °C (<0.0006% per °F from 41 °F to 104 °F)
Maximum altitude: 2000m (6562 ft) to full safety specifications
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.