Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

EXCITATION SOURCE:
Channels: 1
Frequency Range: 10 Hz – 25 MHz user defined ,within instrument frequency range
Output Voltage (pk-pk into 50 Ohms): User selectable between 10 V (default) and 2.5 V
Output Protection: Short circuit protected
Source Impedance: 50 Ohms
MEASUREMENT CHANNELS
Channels: 2
Sampling: Simultaneous
Frequency Range: 10 Hz – 25 MHz
Max. Sampling Rate: 100 MS/s
Input Impedance: 50 Ohms
Recommended Calibration: 1 year
ACCURACY
Magnitude (guaranteed 20 Hz - 2 MHz):
± 0.1 dB (down to -60 dB)
± 0.5 dB (-60 to -100 dB)
DATA COLLECTION
Test Method: Sweep Frequency
PC Comm: USB/Wireless
Frequency Range: 20 Hz - 2 MHz (default), user defined within instrument frequency range
Number of Points:
1045 points (default)
5000 points max per decade (log)
32,000 points max (linear)
Dynamic Range (20 Hz - 2 MHz): >150 dB
IF Bandwidth: <10% of measurement frequency, adaptive
Point Spacing: Variable, Linear or Logarithmic
DATA DISPLAY/EXPORT/ANALYSIS
Tabulation: Frequency/Magnitude/Phase
Export Formats: CSV/IEC/CIGRE, SFRA v5
Plotting: Frequency vs. Magnitude/Phase/ Impedance/Ratio
Analysis: Difference, Cross-Correlation, Leakage Channel, Ratio
PHYSICAL SPECIFICATIONS
Dimensions: 12.25 x 9.5 x 3.7 in (31 x 24 x 9.4 cm)
Weight: 7 lbs (3.2 kg)
Power Supply: 24 VDC (40 W Universal AC in power supply)
Temperature -25° to + 55°C operating -40° to + 85°C storage
Relative Humidity: 0% to 95% non condensing