Transmitter
Power Supply: standard 115/230VAC 50/60Hz, 5 VA max
Velocity: -40 ~ +40 ft/s (-12 ~+12m/s)
Display: LCD 4x16
Units Rate Totalized: User Configured (English and Metric);
Output: 4~20 mA, pulse, relay, RS232; options: up to 8 GB Data logger
Accuracy: ±1.0% of reading at rates >0.5 m/s
±2.0 % of reading at rates <0.5 m="" s="" br=""> Sensitivity: Flow Rate: 0.001ft/s (0.0003m/s)
Repeatability: 0.2% of reading
Security Keypad lockout, access code enable
Dimensions and Weight: 260 x 193 x 80 mm Weight: <2.5kg
Transducer
Liquid Types Supported: Virtually most any liquid containing less than 2% total suspended solids (TSS) or aeration
Suited Liquid Temperature
Std. Temp.: -40℃~121℃
High Temp.: -40℃~250℃
Pipe Size option:
Std M transducer: DN40-1000 (40-1000mm)
L transducer: DN1000-4500 (1000-4500mm)
S transducer: DN15-50 (15-50mm)
K type transducer: DN15-50 (15-50mm)
Dimensions and Weight:
S: Size:42*25*25; weight:<0.2kg
M: Size:60*43*43; weight:<0.5kg
L: Size:80*53*53; weight:<1.0kg
Option transmitter:
Option Tranduser:
Option K-mode Small-Pipe Round Clamp-on Transducer P
Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters
Note: K mode transducers utilize the Round-Clamp method, and the transducers transmitting and receiving sides are connected with the pipe surface thoroughly to acquire enough coupling area, better reliability, stability, etc.