For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

Experience ultra-fast data processing with the Keysight DAQ970A.

03/04/2026 14:46:21

The device incorporates a 6.5-digit multimeter, with a basic DC voltage accuracy of 0.003 percent per year. In full configuration, the system supports up to 120 channels and a scan rate of up to 450 channels per second when using solid-state switching modules.

When multiple measurement channels need to be recorded within the same system, requiring high accuracy and fast processing capabilities, the KEYSIGHT DAQ970A data processing unit is a suitable choice for R&D departments, component testing, and production lines.

Designed with 3 slots, easily expandable to suit different measurement needs

The DAQ970A has a main frame with 3 module slots, supporting a total of 9 types of switching and control modules. Users can configure it to measure temperature, voltage, current, resistance, or perform multi-point tests.

The device integrates LAN and USB ports, allowing control from a PC or access via an internal web browser. The 4.3-inch color screen displays measurements, trend graphs, bar graphs, and histograms directly on the device.

-Measures 14 types of signals in a single system

-Supports the following measurements:

-Temperature with thermocouple, RTD, and thermistor

-DC and AC voltage

-DC and AC current

-2-wire and 4-wire resistance

-Frequency and duty cycle

-Capacitance

-Diode testing

-Distortion

-6.5-digit resolution, equivalent to 22 bits, is suitable for high-precision measurements in laboratories and internal calibration.

See more at: Electrical data logger we distribute

Scans 450 channels per second at high speed, securely storing data

The maximum scanning speed reaches 450 channels per second. With the 4-channel DAQM909A module, the sampling rate reaches up to 800 kSa per second at 24-bit resolution, suitable for dynamic signal measurements or waveform analysis.

Internal memory stores up to 1 million measurements. The device retains up to 100,000 results even after power loss. Users can export data directly to a USB flash drive for storage or transfer configuration to another system.

Set up separate alerts for each measurement channel

Each channel can have its own independent high and low limits. When the value exceeds the threshold, the system activates a TTL alarm output to connect to an external alarm system or automated production line.

The scaling factor allows for unit conversion such as PSI or RPM directly on each channel, convenient for monitoring pressure, rotational speed, or other industrial parameters.

Suitable for R&D, component testing, and production monitoring

The DAQ970A is used in:

- Multi-point temperature data logging in environmental test chambers

- Batch testing of electronic components

- Voltage and current monitoring in production lines

With high accuracy, flexible scalability, and fast processing speed, the DAQ970A is well-suited for multi-channel measurements in professional engineering environments. It is a suitable choice when a stable data acquisition system is needed and easily integrated into existing infrastructure.

Related News

What Is a VLF Very Low Frequency AC Voltage Tester ?
08/26/2026 11:02:45

A VLF very low frequency AC voltage tester is used to assess the insulation condition of cables, transformers, and certain high-voltage electrical equipment. The equipment generates AC test voltage at a very low frequency, typically in the range of 0.05 Hz to 0.1 Hz as referenced in technical sources. This method is particularly useful for testing capacitive loads, such as power cables and certain high-voltage equipment.

Insulation Oil Quality Testing for Electrical Equipment
08/26/2026 10:59:41

Insulation oil testing helps detect changes associated with aging, moisture, and contaminants in the oil. Combining a suitable insulation oil tester with careful sampling procedures and regular data monitoring supports proactive maintenance of electrical equipment and helps maintain the required insulation condition during operation.

Insulation Resistance Tester: Procedures and Safety Precautions
08/25/2026 09:05:54

A megohmmeter must be used according to the proper procedure to ensure operator safety and reliable measurement results. This article covers its operating principle, testing procedure, influencing factors, and essential safety precautions.

How to Measure Ground Resistance Effectively
08/25/2026 09:02:07

A ground resistance tester is used to measure the resistance of a grounding system or ground electrode. Using the correct measurement method gives operators a better basis for identifying changes in the system over time and taking appropriate inspection or corrective measures.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support