Nominal current range: 10 A, AC/DC 100 A, AC/DC
Continuous current range: 0.1 A - 10 A AC/DC; 1 A - 100 A AC/DC
Maximum non-destructive current: 140 A - 2 kHz
Lowest measurable current: 0.1 A
Basic accuracy:
100 mV/A setting: 50 mA to 10 A ±3% of reading +50 mA
10 mV/A setting: 50 mA to 40 A ±4% of reading +50 mA
40 A to 80 A ±12% of reading +50 mA
80 to 100 A ±15% of reading
Useable frequency: DC - 100 kHz
Output level(s): 10 A range: 100 mV/A
100 A range: 10 mV/A
Zero error adjustment: Yes
Safety Specifications
Safety: CAT II, 600 V; CAT III, 300 V
Maximum voltage: 600 V
Mechanical and General Specifications
Battery life: 9 V, 55 h
Maximum conductor diameter: 11.8 mm
Output cable length: 1.6 m
BNC adapter: Yes